3.4 Autochanger Configuration Choices
The following table lists the available configurations choices. An explanation of
how to access and set these configurations is found in ‘‘Setting a Configuration’’
in Section 3.3.1.
Table 3–3 Autochanger Configuration Choices
No.
Function
Default
Options
0
Clear/Save Error Log
(Information Log 0)
Save
Clear - clears the error log
immediately.
Save - saves the error log until
Clear is con figured.
8
No Break on Failure
Off
Off - if a test encounters a failure,
the test stops.
On - if a test encounters a failure,
the test continues.
10
Clear/Save Move Log
(Information Log 10)
Save
Clear - clears the move log
immediately.
Save - saves the move log until
Clear is configured.
11
Clear/Save Runtime Log
(Information Log 11)
Save
Clear - clears the runtime log
immediately.
Save - saves the runtime log until
clear is configured.
Configurations 15 - 20 require
a security code.
15
Prevent Media Removal
(security code required)
Off
On = No mailslot I/O
Off = Normal mailslot I/O
16
Set Default Configurations
(security code required)
Save
Clear - restores default configura-
tions immediately.
Save - maintains all set configura-
tions.
17
Set New Security Code
(security code required)
0-0-0
18
Clear/Save Logs
(security code required)
Save
Clear - clears/zeros the specified
logs.
(continued on next page)
3–12 Product Operation and Configuration
Содержание RW504-ZA
Страница 10: ......
Страница 42: ......
Страница 58: ......
Страница 106: ......
Страница 145: ...Figure 5 22 Optical Disk Library Exploded View Sheet 1 of 3 Removal and Replacement 5 39 ...
Страница 146: ...Figure 5 23 Optical Disk Library Exploded View Sheet 2 of 3 5 40 Removal and Replacement ...
Страница 147: ...Figure 5 24 Optical Disk Library Exploded View Sheet 3 of 3 Removal and Replacement 5 41 ...
Страница 148: ......
Страница 206: ......
Страница 210: ......
Страница 219: ...Voltage Configuration 2 10 Index 5 ...
Страница 220: ......