Table 4–3 (Cont.) Recovery Procedures for Specific Hardware Errors
Error Code
(hex.)
Error
Recovery Procedures
C8
Unable to gain proper
servo control of motors
Run test 60—FRU Isolation Test—verify
failure.
C9
Unable to move picker
motor
Run test 60—FRU Isolation Test—verify
failure.
CA
Unable to move carriage
motor
Run test 60—FRU Isolation Test—verify
failure.
CB
Unable to move either
motor
Run test 60—FRU Isolation Test—verify
failure.
CC
Unable to find a hard
stop while turning the
picker motor
Run test 60—FRU Isolation Test—verify
failure.
CD
Unable to find a hard
stop while turning the
carriage motor
Run test 60—FRU Isolation Test—verify
failure.
CE
Excessive force needed
to move the carriage
leadscrew
Run test 60—FRU Isolation Test—verify
failure.
MISCELLANEOUS ERRORS
FC
The test can only be run from the control
panel or from the RS-232 interface.
FD
The test can only be run from the SCSI
interface.
FE
The test did not run; probably a
configuration error.
FF
Invalid test number.
Troubleshooting and Diagnostics 4–29
Содержание RW504-ZA
Страница 10: ......
Страница 42: ......
Страница 58: ......
Страница 106: ......
Страница 145: ...Figure 5 22 Optical Disk Library Exploded View Sheet 1 of 3 Removal and Replacement 5 39 ...
Страница 146: ...Figure 5 23 Optical Disk Library Exploded View Sheet 2 of 3 5 40 Removal and Replacement ...
Страница 147: ...Figure 5 24 Optical Disk Library Exploded View Sheet 3 of 3 Removal and Replacement 5 41 ...
Страница 148: ......
Страница 206: ......
Страница 210: ......
Страница 219: ...Voltage Configuration 2 10 Index 5 ...
Страница 220: ......