5.4.13 Replacing the Internal UPS Cable
1.
Follow the service access procedure at the beginning of this chapter.
2.
Remove the leadscrew assembly. (See Section 5.4.10.)
3.
Remove the two T-10 screws that secure the UPS cable to the inside of the
disk library back panel.
4.
Pull the UPS cable out through the inside of the autochanger chassis.
5.4.14 Replacing the SCSI Cable
Note
The following assemblies must be removed prior to replacing the SCSI
cable:
•
Leadscrew assembly - see Section 5.4.10
•
Front bezel assembly - see Section 5.4.3
•
Drive assembly - see Section 5.4.7
1.
Follow the service access procedure at the beginning of this chapter.
2.
Remove the four T-10 screws that secure the two SCSI connectors to the disk
library back panel.
3.
Release the large cable clamp at the bottom center section of the disk library
chassis.
4.
Disconnect the drive interface cable from the sensor PCA.
5.
Disconnect the SCSI cable from the controller PCA and feed the cable through
the slot in the sheetmetal beneath the controller PCA.
6.
Pull the SCSI cable assembly out through the center of the disk library
chassis.
Removal and Replacement 5–33
Содержание RW504-ZA
Страница 10: ......
Страница 42: ......
Страница 58: ......
Страница 106: ......
Страница 145: ...Figure 5 22 Optical Disk Library Exploded View Sheet 1 of 3 Removal and Replacement 5 39 ...
Страница 146: ...Figure 5 23 Optical Disk Library Exploded View Sheet 2 of 3 5 40 Removal and Replacement ...
Страница 147: ...Figure 5 24 Optical Disk Library Exploded View Sheet 3 of 3 Removal and Replacement 5 41 ...
Страница 148: ......
Страница 206: ......
Страница 210: ......
Страница 219: ...Voltage Configuration 2 10 Index 5 ...
Страница 220: ......