Connecting SCSI Adapters
8-2
Single Channel SCSI Configuration
To connect SCSI devices, perform the following:
1.
Power down the server.
2.
Disconnect all peripheral devices from the server.
3.
Unlock and remove the side panel.
4.
Connect the cables as shown in Figure 8-1.
5.
Replace and lock the side panel.
6.
Connect all external devices and then power on your server.
7.
Run the SCU utilities to configure your server.
Refer to Chapter 2, “Server Software and Utilities,” and to your SCSI documentation
for additional configuration information.
Figure 8-1 Legend
Component
A
External wide SCSI 67-pin terminator
B
External wide SCSI 67-pin connector
C
Wide SCSI 67-pin connector to CD-ROM drive (option on XLe 6000
configuration)
D
67-pin to 50-pin SCSI adapter
E
Wide SCSI 67-pin connector to tape drive
F
Wide SCSI 67-pin connectors (for internal SCSI devices)
G
Wide SCSI 67-pin connector to SCSI hard disk drive
H
Adaptec 7880 wide SCSI 67-pin connector to main logic board
Содержание Prioris XL 6000 Series
Страница 36: ...Server Components 3 5 PRIORIS XL 6000 Figure 3 3 Server Front View...
Страница 38: ...Server Components 3 7 PRIORIS XL 6000 Figure 3 4 Server Left Side View...
Страница 40: ...Server Components 3 9 PRIORIS XL 6000 Figure 3 5 Server Rear View...
Страница 42: ...Server Components 3 11 PRIORIS XL 6000 Figure 3 6 Main Logic Board Components and Connectors...
Страница 58: ...Installing Additional Memory 5 5 PRIORIS XL 6000 Figure 5 2 Installing a DIMM...
Страница 61: ...Installing Additional Memory 5 8 Figure 5 3 Installing a Video Memory Expansion Chip...
Страница 67: ...Installing Disk and Tape Drives 6 6 Figure 6 1 Installing a 5 Inch Device into the Front Access Drive Bay...
Страница 72: ...Installing Disk and Tape Drives 6 11 PRIORIS XL 6000 Figure 6 5 Connecting an External SCSI Storage Box...
Страница 74: ...Installing Expansion Boards 7 2 Figure 7 1 Expansion Board Slot Locations...
Страница 91: ...Connecting SCSI Adapters 8 3 PRIORIS XL 6000 Figure 8 1 Single Channel SCSI Configuration...
Страница 118: ...Field Service Replacement 11 7 PRIORIS XL 6000 DEC01090 2 Figure 11 2 Removing and Replacing the Diskette Drive...
Страница 120: ...Field Service Replacement 11 9 PRIORIS XL 6000 DEC01090 3 Figure 11 3 Removing and Replacing the CD ROM Drive...
Страница 124: ...Field Service Replacement 11 13 PRIORIS XL 6000 DEC02023 Figure 11 5 Removing and Replacing the Lower Cooling Fan...
Страница 128: ...Field Service Replacement 11 17 PRIORIS XL 6000 Figure 11 7 Replacing the Battery...
Страница 133: ...Field Service IPB 12 3 PRIORIS XL 6000 DEC01104 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Figure 12 1 Server Front View...
Страница 135: ...Field Service IPB 12 5 PRIORIS XL 6000 DEC01105...
Страница 137: ...13 1 PRIORIS XL 6000 13 Field Service Notes 13...
Страница 148: ...Technical Specifications A 7 PRIORIS XL 6000 Figure A 1 Main Logic Board Jumper Locations...