Troubleshooting
10-12
Monitor Troubleshooting
Problem
Possible Cause
Action
Monitor power indicator is
not on.
Monitor is turned off.
Power cord is not
connected.
No power at wall outlet.
Power indicator is
defective.
Turn on the monitor.
Connect the power cord to the
server.
Use another outlet.
Contact your authorized service
provider.
No screen display.
Configuration error.
Monitor brightness and
contrast controls are
incorrectly set.
Monitor has failed.
Run the SCU to configure the
server for video operation.
Adjust the monitor brightness and
contrast controls.
Replace monitor, or contact your
authorized service provider.
Distorted, rolling, or
flickering screen display, or
wrong/uneven color.
Monitor incorrectly
adjusted.
Monitor signal cable
incorrectly installed.
Adjust accordingly.
Straighten any bent connector pins
and then reconnect.
Color monitor displaying
monochrome.
Server was turned on
before the monitor was
turned on.
Turn off the server, turn on the
monitor, then turn the server back
on.
Monitor fails to switch to
high-resolution mode.
Appropriate high-resolution
video drivers are not
installed or incorrectly
installed.
Correctly install all appropriate high-
resolution video drivers. Refer to
the documentation supplied with
your monitor.
Содержание Prioris XL 6000 Series
Страница 36: ...Server Components 3 5 PRIORIS XL 6000 Figure 3 3 Server Front View...
Страница 38: ...Server Components 3 7 PRIORIS XL 6000 Figure 3 4 Server Left Side View...
Страница 40: ...Server Components 3 9 PRIORIS XL 6000 Figure 3 5 Server Rear View...
Страница 42: ...Server Components 3 11 PRIORIS XL 6000 Figure 3 6 Main Logic Board Components and Connectors...
Страница 58: ...Installing Additional Memory 5 5 PRIORIS XL 6000 Figure 5 2 Installing a DIMM...
Страница 61: ...Installing Additional Memory 5 8 Figure 5 3 Installing a Video Memory Expansion Chip...
Страница 67: ...Installing Disk and Tape Drives 6 6 Figure 6 1 Installing a 5 Inch Device into the Front Access Drive Bay...
Страница 72: ...Installing Disk and Tape Drives 6 11 PRIORIS XL 6000 Figure 6 5 Connecting an External SCSI Storage Box...
Страница 74: ...Installing Expansion Boards 7 2 Figure 7 1 Expansion Board Slot Locations...
Страница 91: ...Connecting SCSI Adapters 8 3 PRIORIS XL 6000 Figure 8 1 Single Channel SCSI Configuration...
Страница 118: ...Field Service Replacement 11 7 PRIORIS XL 6000 DEC01090 2 Figure 11 2 Removing and Replacing the Diskette Drive...
Страница 120: ...Field Service Replacement 11 9 PRIORIS XL 6000 DEC01090 3 Figure 11 3 Removing and Replacing the CD ROM Drive...
Страница 124: ...Field Service Replacement 11 13 PRIORIS XL 6000 DEC02023 Figure 11 5 Removing and Replacing the Lower Cooling Fan...
Страница 128: ...Field Service Replacement 11 17 PRIORIS XL 6000 Figure 11 7 Replacing the Battery...
Страница 133: ...Field Service IPB 12 3 PRIORIS XL 6000 DEC01104 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Figure 12 1 Server Front View...
Страница 135: ...Field Service IPB 12 5 PRIORIS XL 6000 DEC01105...
Страница 137: ...13 1 PRIORIS XL 6000 13 Field Service Notes 13...
Страница 148: ...Technical Specifications A 7 PRIORIS XL 6000 Figure A 1 Main Logic Board Jumper Locations...