Server Software and Utilities
2-2
ServerWORKS Quick Launch
Quick Launch is used to install the server’s Network Operating System (NOS).
In addition to providing quick and seamless NOS installation, Quick Launch also
provides drivers, documentation, and the ability to make diskettes of utilities
such as diagnostics. For more information, refer to the Quick Launch Reference
Guide.
System Configuration Utility (SCU)
The SCU enables you check or change your server’s configuration. The SCU is
PCI-aware, and complies with ISA plug and play standards. You must run the
SCU each time you add, remove, or relocate an ISA expansion board.
Each ISA expansion board comes with a diskette that contains a configuration
(.CFG) file. The .CFG file describes the board's characteristics and the server
resources that the board requires. The configuration registers on PCI and plug
and play expansion boards contain the same type of information that an ISA
.CFG file does. Your server’s main logic board also comes with a .CFG file.
The SCU uses the information provided by .CFG files, configuration registers,
NVRAM, and the information that you enter, to specify a particular configuration.
The SCU then configures the server by writing the configuration information to
flash memory.
The SCU stores most of the configuration values in the battery-maintained
memory (NVRAM) of the real-time clock (RTC), and the rest of them in flash
memory. These values take effect each time you boot the server. POST checks
the values against the actual hardware configuration; if they do not agree, it
generates an error message. You must then run the SCU to specify the correct
configuration before you boot the server. POST checks the BIOS Setup.
The SCU modifies the CMOS RAM and NVRAM, under your direction. The
BIOS POST routines and the ISA plug and play Auto Configuration Manager
(ACM) actually configures the hardware.
Содержание Prioris XL 6000 Series
Страница 36: ...Server Components 3 5 PRIORIS XL 6000 Figure 3 3 Server Front View...
Страница 38: ...Server Components 3 7 PRIORIS XL 6000 Figure 3 4 Server Left Side View...
Страница 40: ...Server Components 3 9 PRIORIS XL 6000 Figure 3 5 Server Rear View...
Страница 42: ...Server Components 3 11 PRIORIS XL 6000 Figure 3 6 Main Logic Board Components and Connectors...
Страница 58: ...Installing Additional Memory 5 5 PRIORIS XL 6000 Figure 5 2 Installing a DIMM...
Страница 61: ...Installing Additional Memory 5 8 Figure 5 3 Installing a Video Memory Expansion Chip...
Страница 67: ...Installing Disk and Tape Drives 6 6 Figure 6 1 Installing a 5 Inch Device into the Front Access Drive Bay...
Страница 72: ...Installing Disk and Tape Drives 6 11 PRIORIS XL 6000 Figure 6 5 Connecting an External SCSI Storage Box...
Страница 74: ...Installing Expansion Boards 7 2 Figure 7 1 Expansion Board Slot Locations...
Страница 91: ...Connecting SCSI Adapters 8 3 PRIORIS XL 6000 Figure 8 1 Single Channel SCSI Configuration...
Страница 118: ...Field Service Replacement 11 7 PRIORIS XL 6000 DEC01090 2 Figure 11 2 Removing and Replacing the Diskette Drive...
Страница 120: ...Field Service Replacement 11 9 PRIORIS XL 6000 DEC01090 3 Figure 11 3 Removing and Replacing the CD ROM Drive...
Страница 124: ...Field Service Replacement 11 13 PRIORIS XL 6000 DEC02023 Figure 11 5 Removing and Replacing the Lower Cooling Fan...
Страница 128: ...Field Service Replacement 11 17 PRIORIS XL 6000 Figure 11 7 Replacing the Battery...
Страница 133: ...Field Service IPB 12 3 PRIORIS XL 6000 DEC01104 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Figure 12 1 Server Front View...
Страница 135: ...Field Service IPB 12 5 PRIORIS XL 6000 DEC01105...
Страница 137: ...13 1 PRIORIS XL 6000 13 Field Service Notes 13...
Страница 148: ...Technical Specifications A 7 PRIORIS XL 6000 Figure A 1 Main Logic Board Jumper Locations...