Replacing the Server Battery
The server battery runs the server clock and retains any setup information when it is turned off. If the server
ever fails to retain the correct date, time, or configuration settings when it turned on, replace the server’s
battery.
To replace the battery, perform the following steps:
1)
Record the server’s configuration settings using the SCU.
2) Turn
off
the server. Disconnect any external devices and unplug the power cord from the wall outlet.
Unplug the power cord and monitor cord from the back of the server.
3)
Unlock and remove the left side panel.
4)
Remove the battery.
5)
Install the new battery.
CAUTION
Make sure pin 1 on the battery is correctly aligned with the pin 1 location on the socket
(A, Figure 3 - 16). The pin 1 location on the battery is designated by a white dot in the
lower left corner of the battery. Incorrect installation may cause faulty server operation.
6)
Replace and lock the left side panel.
7)
Reconnect the power cord and monitor cord to the back of the server. Reconnect any external devices and
plug the power cord into the wall outlet.
8)
Reboot and run the SCU and configure the server using the recorded configuration settings from step 1.
Figure 3 - 16 Installing the Server Battery
Содержание PRIORIS MTE
Страница 6: ......
Страница 8: ......
Страница 24: ......
Страница 46: ......
Страница 56: ......
Страница 60: ......
Страница 62: ......
Страница 66: ......
Страница 68: ......
Страница 69: ...Personal Notes...
Страница 70: ...Personal Notes...
Страница 71: ...Personal Notes...
Страница 72: ...Personal Notes...