Operator Control Panel (OCP)
Halt Button
Halt
The Halt button interrupts an operating system session if you
are running DEC OSF/1 or OpenVMS. The Halt light, located on
the Halt button, comes on briefly during the system self-tests.
Thereafter, the Halt light comes on and remains lit whenever DC
power is present and the Halt button is in the ‘‘in’’ position.
Before Power-Up: Pressing the Halt button to the ‘‘in’’ position
before you power up the system boots the SRM console and
prevents the operating system from booting.
•
To boot the DEC OSF/1 or OpenVMS operating system, the
Halt button must be in the ‘‘out’’ position.
•
To boot the Microsoft Windows NT operating system, the
Halt button must be in the ‘‘out’’ position and you must enter
the
arc
command at the SRM console to invoke the ARC
console and access the Boot menu.
Invoking Console Mode: Pressing the Halt button during
a DEC OSF/1 or OpenVMS operating system session invokes
the SRM console. Pressing the Halt button during a Microsoft
Windows NT session has no effect.
Caution
Pressing the Halt button interrupts your DEC OSF/1 or
OpenVMS operating system session. Before pressing the
Halt button, shut down your operating system according
to the operating system shutdown procedure described in
your operating system documentation.
Hardware Components 2–3
Содержание AlphaServer 2000
Страница 4: ......
Страница 12: ......
Страница 18: ......
Страница 33: ...Turning the System On Figure 1 7 Power Up the System MA00016A 1 2 Basic Operation 1 15...
Страница 78: ...System Door and Cover Figure 2 5 Cover Removal MA00076 2 10 Hardware Components...
Страница 84: ......
Страница 132: ...SCSI Buses Figure 3 9 Preferred SCSI Cable Routing with SWXCR Controller MA00083 3 48 Options and Upgrades...
Страница 136: ...Power Supply Configurations Figure 3 11 I O Backplane Jumpers MA00088 J5 J3 J6 J5 J3 J6 1 2 3 52 Options and Upgrades...
Страница 168: ......
Страница 194: ......