Mass Storage Problems Indicated at Power-Up
Mass Storage Problems Indicated at Power-Up
Mass storage failures at power-up are usually indicated by read
fail messages.
•
Table 4–9 provides information for troubleshooting
fixed-media mass storage problems indicated at power-up.
•
Table 4–10 provides information for troubleshooting
removable-media storage problems indicated at power-
up. Use these tables to diagnose the likely cause of the
problem.
Table 4–9 Troubleshooting Fixed-Media Problems
Problem
Symptom
Corrective Action
Drive has failed.
Fault LED for drive is on
(steady).
Replace drive.
Duplicate SCSI IDs (when
removable-media bus is
extended to StorageWorks
shelf).
Drives with duplicate SCSI
IDs are missing from the
show config
display.
Correct removable-media
SCSI IDs.
SCSI ID is set to 7
(reserved for host ID).
Valid drives are missing from
the
show config
display.
One drive may appear seven
times on the
show config
display.
Correct SCSI IDs.
Duplicate host IDs on a
shared bus.
Valid drives are missing from
the
show config
display.
One drive may appear seven
times on the configuration
screen display.
Change host ID using
the
set pk*0_host_id
command described in
the AlphaServer 2000
/2100 Firmware Reference
Guide.
(continued on next page)
Troubleshooting the System
4–21
Содержание AlphaServer 2000
Страница 4: ......
Страница 12: ......
Страница 18: ......
Страница 33: ...Turning the System On Figure 1 7 Power Up the System MA00016A 1 2 Basic Operation 1 15...
Страница 78: ...System Door and Cover Figure 2 5 Cover Removal MA00076 2 10 Hardware Components...
Страница 84: ......
Страница 132: ...SCSI Buses Figure 3 9 Preferred SCSI Cable Routing with SWXCR Controller MA00083 3 48 Options and Upgrades...
Страница 136: ...Power Supply Configurations Figure 3 11 I O Backplane Jumpers MA00088 J5 J3 J6 J5 J3 J6 1 2 3 52 Options and Upgrades...
Страница 168: ......
Страница 194: ......