EISA Bus Problems Indicated at Power-Up
Table 4–11 Troubleshooting EISA Problems
Step
Action
1
Confirm that the EISA module and any cabling are
properly seated.
2
Run the ECU as described in Chapter 3 to:
•
Confirm that the system has been configured with the
most recently installed controller.
•
See what the hardware jumper and switch setting
should be for each ISA controller.
•
See what the software setting should be for each ISA
and EISA controller.
•
See if the ECU deactivated (<>) any controllers to
prevent conflict.
•
See if any controllers are locked (!), which limits the
ECU’s ability to change resource assignments.
3
Confirm that hardware jumpers and switches on ISA
controllers reflect the settings indicated by the ECU.
Start with the last ISA module installed.
4
Check for a bad slot by moving the last installed controller
to a different slot.
5
Call option manufacturer or Digital customer support for
help.
Troubleshooting the System
4–25
Содержание AlphaServer 2000
Страница 4: ......
Страница 12: ......
Страница 18: ......
Страница 33: ...Turning the System On Figure 1 7 Power Up the System MA00016A 1 2 Basic Operation 1 15...
Страница 78: ...System Door and Cover Figure 2 5 Cover Removal MA00076 2 10 Hardware Components...
Страница 84: ......
Страница 132: ...SCSI Buses Figure 3 9 Preferred SCSI Cable Routing with SWXCR Controller MA00083 3 48 Options and Upgrades...
Страница 136: ...Power Supply Configurations Figure 3 11 I O Backplane Jumpers MA00088 J5 J3 J6 J5 J3 J6 1 2 3 52 Options and Upgrades...
Страница 168: ......
Страница 194: ......