Interfaces
Wireless Wide Area Networks (WWANs)
IX10 User Guide
80
14. Type
exit
to exit the Admin CLI.
Depending on your device configuration, you may be presented with an
Access selection
menu
. Type
quit
to disconnect from the device.
Configure the device to reboot when a failure is detected
Using SureLink, you can configure the IX10 device to reboot when it has determined that an interface
has failed.
Required configuration items
n
Enable SureLink.
SureLink can be enabled for both IPv4 and IPv6 configurations. By default, SureLink is enabled
for IPv4 for the preconfigured
Modem
interface. It is disabled for IPv6.
When SureLink is configured for Wireless WANs, SureLink tests are only run if the cellular
modem is connected and has an IP address. Use the
SIM failover
options to configure the IX10
device to automatically recover the modem in the event that it cannot obtain an IP address.
See
Configure a Wireless Wide Area Network (WWAN)
for details about
SIM failover
.
n
Enable device reboot upon interface failure.
n
The type of probe test to be performed, one of:
l
Test another interface's status: Used to create a failover or coupled relationship between
two interfaces. Requires the name of the alternate interface, the IP version to be tested,
and the expected status of the alternate interface (either up or down).
l
Ping: Requires the hostname or IP address of the host to be pinged.
l
DNS query: You can perform a DNS query to a named DNS server, or to the DNS servers
configured for the WAN.
l
HTTP test: Requires the URL of the host to be tested.
l
Test DNS servers configured for this interface: Tests communication with this interface's
DNS servers that are either provided by DHCP, or statically configured.
l
Interface status: Determines if the interface has an IP address assigned to it, that the
physical link is up, and that a route is present to send traffic out of the network interface.
Additional configuration items
n
See
Configure SureLink active recovery to detect modem failures
for optional SureLink
configuration parameters.
To configure the IX10 device to reboot when an interface has failed:
Web
SureLink can be configured for both IPv4 and IPv6.
1. Log into Digi Remote Manager, or log into the local Web UI as a user with full Admin access
rights.
2. Access the device configuration:
Remote Manager:
Содержание IX10
Страница 1: ...IX10 User Guide User Guide Firmware version 22 5 ...
Страница 444: ...Services Simple Network Management Protocol SNMP IX10 User Guide 444 The SNMP page is displayed 4 Click Download ...
Страница 740: ...Monitoring This chapter contains the following topics intelliFlow 741 Configure NetFlow Probe 748 IX10 User Guide 740 ...
Страница 823: ...Command line interface Execute a command from the web interface IX10 User Guide 823 The Admin CLI prompt appears ...
Страница 849: ...Command line interface Command line reference IX10 User Guide 849 Parameters None ...
Страница 858: ...Command line interface Command line reference IX10 User Guide 858 reboot Reboot the system Parameters None ...