System administration
Schedule system maintenance tasks
IX10 User Guide
732
l
If
Duration window
is set to any value other than to
Immediately
or
24 hours
,
the maintenance tasks will run at a random time during the time allotted for
the duration window.
l
If
Duration window
is set to one or more hours, the minutes field in
Start time
is ignored and the duration window will begin at the beginning of the specified
hour.
c. For
Duration window
, select the amount of time that the maintenance tasks will
be run. If
Immediately
is selected, all scheduled tasks will begin at the exact time
specified in
Start time
.
d. For
Frequency
, select whether the maintenance window will be started every day,
or once per week.
n
If
Check if Python Out-of-Service
is set, the maintenance window will only start if the
Python Out-of-Service is set. See
Use Python to set the maintenance window
for further
information.
7. (Optional) Click to enable
Device firmware update
to instruct the system to look for any
updated device firmware during the maintenance window. If updated firmware is found, it will
then be installed.
Note
If your device is managed by a Digi Remote Manager configuration, the configuration
manages the device's firmware version. You should not enable this option.
8. (Optional) Click to enable
Modem firmware update
to instruct the system to look for any
updated modem firmware during the maintenance window. If updated firmware is found, it
will then be installed. Modem firmware update looks for updated firmware both on the local
device and over the network, using either a WAN or cellular connection.
9. (Optional) Click to enable
Configuration check
to allow for the configuration to be updated,
including by custom scripts, during the maintenance window.
10. (Optional) Configure automated checking for device firmware updates:
a. Click to expand
Firmware update check
.
b.
Device firmware update check
is enabled by default. This enables to automated
checking for device firmware updates.
c.
Modem firmware update check
is enabled by default. This enables to automated
checking for modem firmware updates.
d. For Frequency, select how often automated checking for device and modem firmware
should take place. Allowed values are
Daily
,
Weekly
, and
Monthly
. The default is
Daily
.
11. Click
Apply
to save the configuration and apply the change.
Command line
1. Select the device in Remote Manager and click
Actions
>
Open Console
, or log into the IX10
local command line as a user with full Admin access rights.
Depending on your device configuration, you may be presented with an
Access selection
menu
. Type
admin
to access the Admin CLI.
Содержание IX10
Страница 1: ...IX10 User Guide User Guide Firmware version 22 5 ...
Страница 444: ...Services Simple Network Management Protocol SNMP IX10 User Guide 444 The SNMP page is displayed 4 Click Download ...
Страница 740: ...Monitoring This chapter contains the following topics intelliFlow 741 Configure NetFlow Probe 748 IX10 User Guide 740 ...
Страница 823: ...Command line interface Execute a command from the web interface IX10 User Guide 823 The Admin CLI prompt appears ...
Страница 849: ...Command line interface Command line reference IX10 User Guide 849 Parameters None ...
Страница 858: ...Command line interface Command line reference IX10 User Guide 858 reboot Reboot the system Parameters None ...