Virtual Private Networks (VPN)
L2TP
IX10 User Guide
380
Depending on your device configuration, you may be presented with an
Access selection
menu
. Type
admin
to access the Admin CLI.
2. At the command line, type
config
to enter configuration mode:
> config
(config)>
3. Create a new PPP-over-L2TP access concatenator , or edit an existing one:
n
To create a new PPP-over-L2TP access concatenator , see
n
To edit an existing PPP-over-L2TP access concatenator , change to the PPP-over-L2TP
access concatenator node in the configuration schema. For example, for an PPP-over-
L2TP access concatenator named
lac_tunnel
, change to the
lac_tunnel
node in the
configuration schema:
(config)> vpn l2tp lac lac_tunnel
(config vpn l2tp lac lac_tunnel)>
4. Enable active recovery:
(config vpn l2tp lac lac_tunnel)> surelink enable true
(config vpn l2tp lac lac_tunnel)>
5. To configure the device to restart the interface when its connection is considered to have
failed:
(config vpn l2tp lac lac_tunnel)> surelink restart true
(config vpn l2tp lac lac_tunnel)>
This is useful for interfaces that may regain connectivity after restarting, such as a cellular
modem.
6. To configure the device to reboot when the interface is considered to have failed:
(config vpn l2tp lac lac_tunnel)> surelink reboot enable
(config vpn l2tp lac lac_tunnel)>
7. Set the
Interval
between connectivity tests:
(config vpn l2tp lac lac_tunnel)> surelink interval
value
(config vpn l2tp lac lac_tunnel)>
where
value
is any number of weeks, days, hours, minutes, or seconds, and takes the format
number
{
w|d|h|m|s
}.
For example, to set
interval
to ten minutes, enter either
10m
or
600s
:
(config vpn l2tp lac lac_tunnel)> surelink interval 600s
(config vpn l2tp lac lac_tunnel)>
The default is 15 minutes.
8. Determine whether the interface should fail over based on the failure of one of the test targets,
or all of the test targets:
Содержание IX10
Страница 1: ...IX10 User Guide User Guide Firmware version 22 5 ...
Страница 444: ...Services Simple Network Management Protocol SNMP IX10 User Guide 444 The SNMP page is displayed 4 Click Download ...
Страница 740: ...Monitoring This chapter contains the following topics intelliFlow 741 Configure NetFlow Probe 748 IX10 User Guide 740 ...
Страница 823: ...Command line interface Execute a command from the web interface IX10 User Guide 823 The Admin CLI prompt appears ...
Страница 849: ...Command line interface Command line reference IX10 User Guide 849 Parameters None ...
Страница 858: ...Command line interface Command line reference IX10 User Guide 858 reboot Reboot the system Parameters None ...