7
CONFIGURATION COMMAND Reference
This chapter describes the commands and parameters used in the protocol
configuration file config.txt. These are used by the s7_mgt utility to perform
single-shot configuration of the protocol stack at startup.
7.1
Physical Interface Parameters
7.1.1
SS7_BOARD Command
Syntax:
SS7_BOARD <board_id> <board_type> <flags> <code_file>
<run_mode>
Example:
SS7_BOARD 0 SPCI4 0x0043 ss7.dc3 ISUP-L
Command to configure an SPCI4 board in the system.
<board_id>
The logical id of the board within the system in the range 0 ... 15.
<board_type>
The board type within the system. Possible values are:
•
SPCI2S
for Dialogic
®
DSI SPCI2S Network Interface Boards.
•
SPCI4
for Dialogic
®
DSI SPCI4 Network Interface Boards boards.
<flags>
A 16 bit value that provides additional level 1 configuration for the board. The
meaning of each bit may vary with different board types. The bits in the flags
field are used as follows:
Bit 0
controls the reference source used for on-board clocks when acting as
CT bus Primary Master. If set to 1 then the clock is recovered from one of the
line interfaces. If set to zero then the on-board clock oscillator is used.
Bit 1
is reserved for future use and must always be set to 1.
Bit 6
and
7
together select the initial clocking mode for the CT bus as shown
in the following table. The clocking mode can subsequently modified
dynamically using the MVD_MSG_CNFCLOCK message: