6 Message Reference
58
ais_gen
Description
0
Do not change AIS / Blue alarm generation mode.
1
Disabled - do not generate AIS / Blue alarm.
2
Enabled - generate AIS / Blue alarm.
rai_gen
The mode used to generate the Remote Alarm Indication (Yellow Alarm)
taken from the following table:
rai_gen
Description
0
Do not change RAI / Yellow alarm generation mode.
1
Disabled - do not generate RAI / Yellow alarm.
2
Forced active - generate RAI / Yellow alarm.
3
Automatic generation of RAI / Yellow alarm upon loss of
synchronization.
loop_mode
The diagnostic loop back mode taken from the following table:
loop_mode
Description
0
Do not change diagnostic loop back mode.
1
Disabled - remove any diagnostic loop.
2 Payload
loopback.
3 Remote
loopback.
4 Local
loopback.
Status Response
The confirmation message (if requested) indicates success by status of zero.
On error, the following status values can be found in the confirmation
message.
Value
Mnemonic
Description
0x01 None
Invalid
framer
ID.
0x02 None
Invalid
message
length.
0x03
None
Control parameters are not consistent with the type of device being
controlled or with each other.