6 Message Reference
68
timeslot
The timeslot number on the T1/E1 line interface unit on which the fixed data
is transmitted. The valid range for
timeslot
is 1 to 31 for an E1 interface and
1 to 24 for a T1 interface.
pattern
The value of the fixed data to be generated. The value must be in the range 0
to 255. Typical values are 0xff for an "all ones" idle pattern, or 0x2a for an
ITU-T E1 idle pattern.
Status Response
The confirmation message (if requested) indicates success by status of zero.
On error, the following status values can be found in the confirmation
message.
Value
Mnemonic
Description
0xd2
MVIP_INVALID_STREAM
Invalid stream specified in listen request.
0xd3
MVIP_INVALID_TIMESLOT
Invalid timeslot specified in listen request.
0xff
None
Fixed pattern generation request failed.
6.3.9
Reset Switch Request
Synopsis:
Resets the digital switch to its default state in accordance with the current
board configuration.
Message Format:
MESSAGE HEADER
Field Name
Meaning
type MVD_MSG_RESETSWX
(0x7e00)
id
0
src
Sending Module ID
dst MVD_TASK_ID
(0x10)
rsp_req
used to request a confirmation
hclass
0
status
0
err_info
0
len
0