![DENTSPLY inLab MC X5 Скачать руководство пользователя страница 87](http://html1.mh-extra.com/html/dentsply/inlab-mc-x5/inlab-mc-x5_operating-instructions-manual_2483578087.webp)
64 78 759 D3608
D3608
.
201.01.07
.
02 10.2017
87
Dentsply Sirona
7 Maintenance and cleaning
Operating Instructions inLab MC X5
7.8 Procedure for processing sintering metal
båÖäáëÜ
7.8.4
Cleaning the coolant tank
7.8.4.1
Emptying the cooling tank
✔
There is a 10l-20l collecting tank available.
1. Draw off the machine-sided tank inlet hose (A) with the large diameter
as well as the thin coolant supply hose (B) from the tank. Pay
attention to leaking residual liquid and catch it with a separate
collecting container, if necessary.
2. Leave the tank to rest overnight until the particles have settled on the
bottom.
ª
The particles have largely settled on the bottom.
3. Open the tank lid clip (C) and pull the filter system out. Pay attention
to any remainder liquid.
4. Clear the coolant (unclouded liquid) by carefully pouring it out until the
remaining solids become visible. Ensure that approximately 1/5 of the
coolant remains in the tank.
5. Pan the tank vigorously several times in circular movements until the
deposited solids once again mix with the remaining coolant. Prevent
the fluid from escaping from the tank.
6. Empty approx. 1/2 of the remaining contents of the tank into the
collecting vessel provided.
7. Pan the tank vigorously in circular movements again until as much of
the remaining solids as possible can be rinsed out using the
remaining coolant.
8. Empty the residual contents into the collecting vessel provided.
7.8.4.2
Rinsing and emptying the water tank
1. Fill the tank approx. 1/4 full with water.
2. Pan the tank several times in circular movements.
3. Empty the residual contents into the collecting vessel provided. Pan
the tank several times in circular movements in the meantime where
necessary.
NOTICE
The tank may become unusable
Regularly check the condition of the deposited solids and clean the tank
in good time to prevent the solids from hardening in the tank (after
approx. 5 discs, the milling residue should be emptied into a collection
tank).
A
C
B
D