5 Commissioning
Operating Instructions inLab MC X5
5.2 Putting the unit into operation
båÖäáëÜ
5.2.7
Installing and configuring the unit
5.2.7.1
Installing the unit
You must connect the unit to the PC before putting it into operation. This
is described in the chapter "Connecting the PC/interfaces [ → 33]".
5.2.7.1.1
Automatic unit search
✔
The unit is connected to the PC using a direct connection via Ethernet
cable.
✔
The unit is switched on.
1. Start the
"inLab CAM"
software.
2. Click on the
"Machine and Instrument tray Management"
button in
the system menu.
3. Click on the
"Scan for New Devices"
button.
ª
All units connected to the PC are recognized.
4. Enter a name for the new unit.
IMPORTANT
The inLab MC X5 can be operated with both a static as well as an
automatically assigned IP address.
From the factory the inLab MC X5 is always configured with a static IP
address. The standard IP address is as follows: 192.168.230.xy. The
digits x and y are made up from the last two digits of the unit serial
number. These can be found on the label on the rear of the device If the
serial number ends in "00" then the xy value is always"100".
The MAC address for the network card can be found on the machine's
configuration menu.
To change the IP configuration always establish a direct connection with
static IP address to your PC's network card. The network address for the
inLab 4-PC used is 192.168.230.101. The subnet mask is
255.255.255.0.