i.e. 4 subindexes in PDO data buffer can be occupied at one time. For example, set up the TPDO
mapping parameter of DVP-FPMC as H200A, H2, H30, indicating the 2
nd
subindex of H200A with data
length 48 bits. In this case, the subindex 2 ~4 in PDO data buffer will be occupied.
T PDO Map pin g
FPMC
PD O D ata B u ffer
H2
H2 00A
H1 A0 0
C R #
Sub Index 1
O D
Ind ex
2 00 A
H3 0
Sub Index 2
Sub Index 3
Sub Index 4
2 00 A
2 00 A
2 00 A
z
Set up PDO data
Entre the data to be transmitted by PDO in the above data buffer of OD index. For example, set up the
TPDO data buffer of DVP-FPMC as subindex 2~4 of OD index 200A, and the RPDO data buffer of Slave
as subindex 1~3 of OD index 203F. When the communication executes, data transmission will be
executed according to the specified synchronization cycle settiing.
200A
200A
200A
Data to Slave
Data to Slave
Data to Slave
203F
203F
203F
Data from DVP-FP MC
Data from DVP-FP MC
Data from DVP-FP MC
FPMC
Slave
PDO Data Buf fer
PDO Data Buf fer
13.7 DVP-FPMC
Ethernet
Applications
DVP-FPMC supports Ethernet communication between DVP-FPMC and Ethernet devices, or between
DVP-FPMC and PC through PMSoft for program upload/download and monitoring. For external wirings, the
user only needs to connect the Ethernet COM ports on DVP-FPMC and the device to be connected through
an Ethernet cable. Please also refer to detailed hardware configurations on 13.3 Product Profile &
Installation. When connecting with PC, the Ethernet indicator will be ON in nomal connection status. If the
indicator is OFF, please check the hardware configuration or PC settings.
13.7.1 Communication between DVP-FPMC and HMI
Configuration
The example applies 2 sets of DVP-20PM with DVP-FPMC for data exange between PLCs and HMI
(DOP-B10E615) through Ethernet. The hardware configuration is as the diagram below. The control purpose
is to control Y0~Y7 on both PLCs by HMI.
Содержание DVP-10PM
Страница 1: ......
Страница 45: ...2 Hardware Specifications and Wiring DVP PM Application Manual 2 30 MEMO...
Страница 125: ...3 Functions of Devices in DVP PM DVP PM Application Manual 3 80 MEMO...
Страница 341: ...8 Application Examples DVP PM Application Manual 8 2 Trajectory 3 Trajectory 4...
Страница 427: ...9 Electrical CAM DVP PM Application Manual 9 74...
Страница 437: ...10 Encrypting User Program DVP PM Application Manual 10 10 MEMO...
Страница 458: ...11 G code Application DVP PM Application Manual 11 21 B O100 main program...
Страница 561: ...14 Appendix DVP PM Application Manual 14 4 MEMO...