5
Categories and Use of Basic Application Instructions
DVP-PM Operation Instruction
5-114
API Mnemonic
Operands
Function
132
D TAN P
Tangent
Controllers
20PM
10PM
Bit Devices
Word Devices
Program Steps
Type
OP
X Y M S F H
KnX
KnY KnM KnS T
C
D
V
Z
S
*
*
D
*
DTAN, DTANP: 6 steps
Operands:
S
: Source device (0
°≦
S
<
360
°
)
D
: Operation result
Explanations:
1. TAN instruction performs tangent operation on
S
and stores the result in
D
.
2. F refers to floating point input. Be sure to add a decimal point when using it.
3. Only 32-bit instructions DTAN and DTANP are applicable.
4. The value in
S
can be set as radian or degree by Radian/Degree selection flag
M1760/M1920 = OFF indicates radian mode. RAD = degree
×π
/180.
M1760/M1920 = ON indicates degree mode. Degree range: 0
°≦
degree
<
360
°
.
5. If the result = 0, zero flag will be ON.
6. Flags:
OX
O100
Zero flag
M1808
M1968
Radian/Degree flag
M1760
M1920
7. See the figure below for the relation between the radian and the operation result.
R
S
-2
3
2
-2
2
3
2
2
2
-
1
-1
0
-
S: Radian
R: Result (TAN value)
Program Example 1:
Radian/degree selection flag = OFF indicates radian mode. When X0 = ON, DTAN instruction performs tangent
operation on the radian value in (D1, D0) and stores the TAN value in (D11, D10) in binary floating format..
M1002
RST
X0
DTAN
D0
D10
Degree/radian
flag
Содержание DVP-10PM
Страница 1: ......
Страница 45: ...2 Hardware Specifications and Wiring DVP PM Application Manual 2 30 MEMO...
Страница 125: ...3 Functions of Devices in DVP PM DVP PM Application Manual 3 80 MEMO...
Страница 341: ...8 Application Examples DVP PM Application Manual 8 2 Trajectory 3 Trajectory 4...
Страница 427: ...9 Electrical CAM DVP PM Application Manual 9 74...
Страница 437: ...10 Encrypting User Program DVP PM Application Manual 10 10 MEMO...
Страница 458: ...11 G code Application DVP PM Application Manual 11 21 B O100 main program...