P2 - 25
NLP
Low-pass Filter Time Constant of Resonance
Suppression
Communication Addr.: 0219H
Default: 2 (1KW and below models) or
Applicable Control Mode: P/S/T
5 (1KW and below above models)
Range: 0~1000
Unit: msec
This parameter is used to set low-pass filter time constant of resonance suppression.
0: Disabled
P2 - 26
DST
External Anti-Interference Gain
Communication Addr.: 021AH
Default: 0
Applicable Control Mode: P/S/T
Range: 0~30000
Unit: 0.001
In easy mode, the value of this parameter is the default of the easy mode automatically.
0: Disabled
P2 - 27
GCC
Gain Switching Selection
Communication Addr.: 021BH
Default: 0
Applicable Control Mode: P/S
Range: 0~4
Setting:
0: Disabled
1: Gain switching signal (GAINUP) is On.
2: In position control mode, position deviation is higher than the setting value of P2-29.
3: Position command frequency is higher than the setting value of P2-29.
4: Servo motor rotation speed is higher than the setting value of P2-29.
P2 - 28
GUT
Gain Switching Time Constant
Communication Addr.: 021CH
Default: 10
Applicable Control Mode: P/S
Range: 0~1000
Unit: 10 msec
This parameter is used to set the time constant when changing the smooth gain.
0: Disabled
P2 - 29
GPE
Gain Switching Condition
Communication Addr.: 021DH
Default: 10000
Applicable Control Mode: P/S
Range: 0~30000
Unit: Pulse, Kpps, rpm
This parameter is used to set the value of gain switching condition (Pulse error, Kpps, rpm)
selected in P2-27.
0: Disabled. The setting value will be different depending on the different gain switching condition.