Chapter 6 Control Modes of Operation
ASDA-A User Manual
4th Edition 2005/11/30, HE03
© DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED
6-34
6-5 Control
Modes
Selection
Except signal control mode operation, ASDA-A series AC drive also provide Pt-S, Pr-S, S-T, Pt-T, Pr-T these
five multiple modes for user to select.
1
α
Speed / Position mode selection: Pt-S, Pr-S
2
α
Speed / Torque mode selection: S-T
3
α
Torque / Position mode selection: Pt-T, Pr-T
Mode
Name
Code
Description
Pt-S 06
Either
Pt
or
S
control mode can be selected via the Digital
Inputs (DI)
Pt-T 07
Either
Pt
or
T
control mode can be selected via the Digital
Inputs (DI)
Pr-S 08
Either
Pr
or
S
control mode can be selected via the Digital
Inputs (DI)
Pr-T 09
Either
Pr
or
T
control mode can be selected via the Digital
Inputs (DI)
Dual Mode
S-T 10
Either
S
or
T
control mode can be selected via the Digital Inputs
(DI)
Sz and Tz mode selection is not provided. In order to avoid using too much DI inputs, we recommend that
user can use external analog signal as input command in speed and torque mode to reduce the use of DI
inputs (
SPD0~1 or TCM0~1
). In position mode, we recommend that users can use Pt mode to input pulse to
reduce the use of DI inputs (
POS0~2
).
Please refer to
table 3.H
and
table 3.I
in
section 3-3-2
to see the default DI/DO signal in different modes.