Chapter 7 Servo Parameters
|
ASDA-AB Series
Revision January 2009
7-19
Others
Control
Mode
Parameter Name
Function
Default Unit
Pt Pr S T
Related
Section of
User
Manual
P1-31
MSE Motor Type Selection
0
N/A
{
{
{
{
---
P1-32
LSTP Motor Stop Mode Selection
0
N/A
{
{
{
{
---
P1-37 GDR
Ratio of Load Inertia to Servo Motor
Inertia
5.0 times
{
{
{
{
6.3.6
P1-52
RES1 Regenerative Resistor Value
N/A
Ohm
{
{
{
{
6.6.3
P1-53 RES2
Regenerative
Resistor
Capacity
N/A Watt
{
{
{
{
6.6.3
P1-57 Reserved
---
P1-58 Reserved
---
P1-59 Reserved
---
P1-60 Reserved
---
P1-61 Reserved
---
P2-08
■
PCTL Special Factory Setting
0 N/A
{
{
{
{
---
P2-30
■
INH
Auxiliary Function
0 N/A
{
{
{
{
---
P2-34
SDEV Overspeed Warning Condition
5000
r/min
{
---
P2-35
PDEV Excessive Error Warning Condition
30000
pulse
{
{
---
P2-51 SRON
Servo
ON
0 N/A
{
{
{
{
12.6
P2-63
TSCA Proportion Value Setting
0
times
{
{
{
---
P2-65 GBIT
Special
Function
0 N/A
{
{
{
---
Explanation of symbols (marked after parameter)
(
★
) Read-only
register.
(
▲
)
Parameter cannot be set when Servo On (when the servo drive is enabled).
(
●
)
Parameter is effective only after the servo drive is restarted (after switching power off and on).
(
■
)
Parameter setting values are not retained when power is off.
Содержание AC Servo Drive ASDA-AB
Страница 1: ......
Страница 13: ...Table of Contents ASDA AB Series Revision January 2009 This page intentionally left blank...
Страница 20: ...Chapter 1 Unpacking Check and Model Explanation ASDA AB Series Revision January 2009 1 7 110V models...
Страница 27: ...Chapter 3 Connections and Wiring ASDA AB Series 3 2 Revision January 2009 Figure 3 2 110V Servo Drive...
Страница 67: ...Chapter 3 Connections and Wiring ASDA AB Series 3 42 Revision January 2009 This page intentionally left blank...
Страница 85: ...Chapter 5 Trial Run and Tuning Procedure ASDA AB Series 5 8 Revision January 2009...
Страница 103: ...Chapter 5 Trial Run and Tuning Procedure ASDA AB Series 5 26 Revision January 2009 This page intentionally left blank...
Страница 149: ...Chapter 6 Control Modes of Operation ASDA AB Series 6 46 Revision January 2009 This page intentionally left blank...
Страница 246: ...Chapter 8 MODBUS Communications ASDA AB Series Revision January 2009 8 3 Cable Connection...
Страница 265: ...Chapter 9 Maintenance and Inspection ASDA AB Series 9 4 Revision January 2009 This page intentionally left blank...
Страница 275: ...Chapter 10 Troubleshooting ASDA AB Series 10 10 Revision January 2009 This page intentionally left blank...
Страница 282: ...Chapter 11 Specifications ASDA AB Series Revision January 2009 11 7 11 3 Servo Motor Speed Torque Curves...
Страница 307: ...Chapter 12 Application Examples ASDA AB Series 12 10 Revision January 2009...
Страница 333: ...Chapter 12 Application Examples ASDA AB Series 12 36 Revision January 2009 8 B A 2 5 Position SPEED Z pulse...
Страница 335: ...Chapter 12 Application Examples ASDA AB Series 12 38 Revision January 2009 Connecting to Delta DVP 01PU...
Страница 336: ...Chapter 12 Application Examples ASDA AB Series Revision January 2009 12 39 Connecting to Mitsubishi FX1PG...
Страница 337: ...Chapter 12 Application Examples ASDA AB Series 12 40 Revision January 2009 Connecting to Mitsubishi FX2N1PG...
Страница 338: ...Chapter 12 Application Examples ASDA AB Series Revision January 2009 12 41 Connecting to Mitsubishi AD75...
Страница 339: ...Chapter 12 Application Examples ASDA AB Series 12 42 Revision January 2009 This page intentionally left blank...
Страница 353: ...Appendix A Accessories ASDA AB Series A 14 Revision January 2009 This page intentionally left blank...
Страница 356: ...Appendix A Accessories ASDA AB Series Revision January 2009 B 3 Figure 1 Saddle on both ends Saddle on one end Figure 2...