Chapter 7 Servo Parameters
|
ASDA-AB Series
Revision January 2009
7-87
P4 - 20
DOF1
Analog Monitor Output Drift Adjustment (CH1)
Communication Addr.: 0414H
Default: Factory setting
Related Section:
Applicable Control Mode: ALL
Section 6.4.4
Unit: mV
Range: -800~800
Settings:
This parameter cannot be reset.
P4 - 21
DOF2
Analog Monitor Output Drift Adjustment (CH2)
Communication Addr.: 0415H
Default: Factory setting
Related Section: N/A
Applicable Control Mode: ALL
Section 6.4.4
Unit: mV
Range: -800~800
Settings:
This parameter cannot be reset.
P4 - 22
SAO
Analog Speed Input Offset
Communication Addr.: 0416H
Default: 0
Related Section: N/A
Applicable Control Mode: S
Unit: mV
Range: -5000~5000
Settings:
The users can use this parameter to adjust analog speed input offset value manually.
P4 - 23
TAO
Analog Torque Input Offset
Communication Addr.: 0417H
Default: 0
Related Section: N/A
Applicable Control Mode: T
Unit: mV
Range: -5000~5000
Settings:
The users can use this parameter to adjust analog torque input offset value manually.
Содержание AC Servo Drive ASDA-AB
Страница 1: ......
Страница 13: ...Table of Contents ASDA AB Series Revision January 2009 This page intentionally left blank...
Страница 20: ...Chapter 1 Unpacking Check and Model Explanation ASDA AB Series Revision January 2009 1 7 110V models...
Страница 27: ...Chapter 3 Connections and Wiring ASDA AB Series 3 2 Revision January 2009 Figure 3 2 110V Servo Drive...
Страница 67: ...Chapter 3 Connections and Wiring ASDA AB Series 3 42 Revision January 2009 This page intentionally left blank...
Страница 85: ...Chapter 5 Trial Run and Tuning Procedure ASDA AB Series 5 8 Revision January 2009...
Страница 103: ...Chapter 5 Trial Run and Tuning Procedure ASDA AB Series 5 26 Revision January 2009 This page intentionally left blank...
Страница 149: ...Chapter 6 Control Modes of Operation ASDA AB Series 6 46 Revision January 2009 This page intentionally left blank...
Страница 246: ...Chapter 8 MODBUS Communications ASDA AB Series Revision January 2009 8 3 Cable Connection...
Страница 265: ...Chapter 9 Maintenance and Inspection ASDA AB Series 9 4 Revision January 2009 This page intentionally left blank...
Страница 275: ...Chapter 10 Troubleshooting ASDA AB Series 10 10 Revision January 2009 This page intentionally left blank...
Страница 282: ...Chapter 11 Specifications ASDA AB Series Revision January 2009 11 7 11 3 Servo Motor Speed Torque Curves...
Страница 307: ...Chapter 12 Application Examples ASDA AB Series 12 10 Revision January 2009...
Страница 333: ...Chapter 12 Application Examples ASDA AB Series 12 36 Revision January 2009 8 B A 2 5 Position SPEED Z pulse...
Страница 335: ...Chapter 12 Application Examples ASDA AB Series 12 38 Revision January 2009 Connecting to Delta DVP 01PU...
Страница 336: ...Chapter 12 Application Examples ASDA AB Series Revision January 2009 12 39 Connecting to Mitsubishi FX1PG...
Страница 337: ...Chapter 12 Application Examples ASDA AB Series 12 40 Revision January 2009 Connecting to Mitsubishi FX2N1PG...
Страница 338: ...Chapter 12 Application Examples ASDA AB Series Revision January 2009 12 41 Connecting to Mitsubishi AD75...
Страница 339: ...Chapter 12 Application Examples ASDA AB Series 12 42 Revision January 2009 This page intentionally left blank...
Страница 353: ...Appendix A Accessories ASDA AB Series A 14 Revision January 2009 This page intentionally left blank...
Страница 356: ...Appendix A Accessories ASDA AB Series Revision January 2009 B 3 Figure 1 Saddle on both ends Saddle on one end Figure 2...