Chapter 10 Troubleshooting
|
ASDA-AB Series
Revision January 2009
10-3
10.2 Potential Cause and Corrective Actions
Servo Drive Fault Messages
: Overcurrent
Potential Cause
Checking Method
Corrective Actions
Short-circuit at drive
output (U, V, W)
1. Check the wiring connections between drive
and motor.
2. Check if the wire is short-circuited.
Repair the short-circuited and avoid
metal conductor being exposed.
Motor wiring error
Check if the wiring steps are all correct when
connecting motor to drive.
Follow the wiring steps in the user
manual to reconnect wiring.
IGBT error
Heat sink overheated
Please contact your distributor for
assistance or contact with Delta.
Control parameter
setting error
Check if the setting value exceeds the factory
default setting.
Set the setting back to factory
default setting and then reset and
adjust the parameter setting again.
Control command
setting error
Check if the control input command is unstable
(too much fluctuation).
1. Ensure that input command
frequency is stable (too much
fluctuation).
2. Activate filter function.
: Overvoltage
Potential Cause
Checking Method
Corrective Actions
The main circuit voltage
has exceeded its
maximum allowable
value.
Use voltmeter to check whether the input
voltage falls within the rated input voltage. (For
voltage specification, please refer to section
11.1 in Chapter11.)
Use correct power supply or
stabilizing power.
Input power error
(Incorrect power input)
Use voltmeter to check whether the input
voltage is within the specified limit.
Use correct power supply or
stabilizing power.
: Undervoltage
Potential Cause
Checking Method
Corrective Actions
The main circuit voltage
is below its minimum
specified value.
Check whether the wiring of main circuit input
voltage is normal.
Reconfirm voltage wiring.
No input voltage at
main circuit.
Use voltmeter to check whether input voltage at
main circuit is normal.
Reconfirm power switch.
Input power error
(Incorrect power input)
Use voltmeter to check whether the input
voltage is within the specified limit.
Use correct power supply or serial
stabilizing power.
: Z Pulse shift
Potential Cause
Checking Method
Corrective Actions
Encoder is damage.
Check Encoder for the damage.
Repair or replace the motor.
Encoder is loose.
Examine the Encoder connector.
Install the motor again.
Содержание AC Servo Drive ASDA-AB
Страница 1: ......
Страница 13: ...Table of Contents ASDA AB Series Revision January 2009 This page intentionally left blank...
Страница 20: ...Chapter 1 Unpacking Check and Model Explanation ASDA AB Series Revision January 2009 1 7 110V models...
Страница 27: ...Chapter 3 Connections and Wiring ASDA AB Series 3 2 Revision January 2009 Figure 3 2 110V Servo Drive...
Страница 67: ...Chapter 3 Connections and Wiring ASDA AB Series 3 42 Revision January 2009 This page intentionally left blank...
Страница 85: ...Chapter 5 Trial Run and Tuning Procedure ASDA AB Series 5 8 Revision January 2009...
Страница 103: ...Chapter 5 Trial Run and Tuning Procedure ASDA AB Series 5 26 Revision January 2009 This page intentionally left blank...
Страница 149: ...Chapter 6 Control Modes of Operation ASDA AB Series 6 46 Revision January 2009 This page intentionally left blank...
Страница 246: ...Chapter 8 MODBUS Communications ASDA AB Series Revision January 2009 8 3 Cable Connection...
Страница 265: ...Chapter 9 Maintenance and Inspection ASDA AB Series 9 4 Revision January 2009 This page intentionally left blank...
Страница 275: ...Chapter 10 Troubleshooting ASDA AB Series 10 10 Revision January 2009 This page intentionally left blank...
Страница 282: ...Chapter 11 Specifications ASDA AB Series Revision January 2009 11 7 11 3 Servo Motor Speed Torque Curves...
Страница 307: ...Chapter 12 Application Examples ASDA AB Series 12 10 Revision January 2009...
Страница 333: ...Chapter 12 Application Examples ASDA AB Series 12 36 Revision January 2009 8 B A 2 5 Position SPEED Z pulse...
Страница 335: ...Chapter 12 Application Examples ASDA AB Series 12 38 Revision January 2009 Connecting to Delta DVP 01PU...
Страница 336: ...Chapter 12 Application Examples ASDA AB Series Revision January 2009 12 39 Connecting to Mitsubishi FX1PG...
Страница 337: ...Chapter 12 Application Examples ASDA AB Series 12 40 Revision January 2009 Connecting to Mitsubishi FX2N1PG...
Страница 338: ...Chapter 12 Application Examples ASDA AB Series Revision January 2009 12 41 Connecting to Mitsubishi AD75...
Страница 339: ...Chapter 12 Application Examples ASDA AB Series 12 42 Revision January 2009 This page intentionally left blank...
Страница 353: ...Appendix A Accessories ASDA AB Series A 14 Revision January 2009 This page intentionally left blank...
Страница 356: ...Appendix A Accessories ASDA AB Series Revision January 2009 B 3 Figure 1 Saddle on both ends Saddle on one end Figure 2...