Revision January 2009
6-1
Chapter 6 Control Modes of Operation
6.1 Control Modes of Operation
The Delta ASDA-AB series
can be programmed to provide six single and five dual modes of operation. Their
operation and description is listed in the following table.
Mode
Code
Description
External Position Control
Pt
Position control for the servo motor is achieved via an
external pulse command.
Internal Position Control
Pr
Position control for the servo motor is achieved via by 8
commands stored within the servo controller. Execution of
the 8 positions is via Digital Input (DI) signals.
Speed Control
S
Speed control for the servo motor can be achieved via
parameters set within the controller or from an external
analog -10 ~ +10 V
DC
command. Control of the internal
speed parameters is via the Digital Inputs (DI). (A maximum
of three speeds can be stored internally).
Internal Speed Control
Sz
Speed control for the servo motor is only achieved via
parameters set within the controller. Control of the internal
speed parameters is via the Digital Inputs (DI). (A maximum
of three speeds can be stored internally).
Torque Control
T
Torque control for the servo motor can be achieved via
parameters set within the controller or from an external
analog -10 ~ +10 V
DC
command. Control of the internal
torque parameters is via the Digital Inputs (DI). (A
maximum of three torque levels can be stored internally).
Single
Mode
Internal Torque Control
Tz
Torque control for the servo motor is only achieved via
parameters set within the controller. Control of the internal
torque parameters is via the Digital Inputs (DI). (A
maximum of three torque levels can be stored internally).
Pt-S Either Pt or S control mode can be selected via the Digital
Inputs (DI)
Pt-T Either Pt or T control mode can be selected via the Digital
Inputs (DI)
Pr-S Either Pr or S control mode can be selected via the Digital
Inputs (DI)
Pr-T Either Pr or T control mode can be selected via the Digital
Inputs (DI)
Dual Mode
S-T
Either S or T control mode can be selected via the Digital
Inputs (DI)
The steps of changing mode:
(1)
Switching the servo drive to Servo Off status. Turning SON signal of Digit input to be off can complete
this action.
(2)
Using parameter P1-01. (Refer to chapter 7).
(3)
After the setting is completed, cut the power off and restart the drive again.
Содержание AC Servo Drive ASDA-AB
Страница 1: ......
Страница 13: ...Table of Contents ASDA AB Series Revision January 2009 This page intentionally left blank...
Страница 20: ...Chapter 1 Unpacking Check and Model Explanation ASDA AB Series Revision January 2009 1 7 110V models...
Страница 27: ...Chapter 3 Connections and Wiring ASDA AB Series 3 2 Revision January 2009 Figure 3 2 110V Servo Drive...
Страница 67: ...Chapter 3 Connections and Wiring ASDA AB Series 3 42 Revision January 2009 This page intentionally left blank...
Страница 85: ...Chapter 5 Trial Run and Tuning Procedure ASDA AB Series 5 8 Revision January 2009...
Страница 103: ...Chapter 5 Trial Run and Tuning Procedure ASDA AB Series 5 26 Revision January 2009 This page intentionally left blank...
Страница 149: ...Chapter 6 Control Modes of Operation ASDA AB Series 6 46 Revision January 2009 This page intentionally left blank...
Страница 246: ...Chapter 8 MODBUS Communications ASDA AB Series Revision January 2009 8 3 Cable Connection...
Страница 265: ...Chapter 9 Maintenance and Inspection ASDA AB Series 9 4 Revision January 2009 This page intentionally left blank...
Страница 275: ...Chapter 10 Troubleshooting ASDA AB Series 10 10 Revision January 2009 This page intentionally left blank...
Страница 282: ...Chapter 11 Specifications ASDA AB Series Revision January 2009 11 7 11 3 Servo Motor Speed Torque Curves...
Страница 307: ...Chapter 12 Application Examples ASDA AB Series 12 10 Revision January 2009...
Страница 333: ...Chapter 12 Application Examples ASDA AB Series 12 36 Revision January 2009 8 B A 2 5 Position SPEED Z pulse...
Страница 335: ...Chapter 12 Application Examples ASDA AB Series 12 38 Revision January 2009 Connecting to Delta DVP 01PU...
Страница 336: ...Chapter 12 Application Examples ASDA AB Series Revision January 2009 12 39 Connecting to Mitsubishi FX1PG...
Страница 337: ...Chapter 12 Application Examples ASDA AB Series 12 40 Revision January 2009 Connecting to Mitsubishi FX2N1PG...
Страница 338: ...Chapter 12 Application Examples ASDA AB Series Revision January 2009 12 41 Connecting to Mitsubishi AD75...
Страница 339: ...Chapter 12 Application Examples ASDA AB Series 12 42 Revision January 2009 This page intentionally left blank...
Страница 353: ...Appendix A Accessories ASDA AB Series A 14 Revision January 2009 This page intentionally left blank...
Страница 356: ...Appendix A Accessories ASDA AB Series Revision January 2009 B 3 Figure 1 Saddle on both ends Saddle on one end Figure 2...