Chapter 6 Control Modes of Operation
|
ASDA-AB Series
6-2
Revision January 2009
The following sections describe the operation of each control mode, including control structure, command
source and loop gain adjustment, etc.
6.2 Position Control Mode
The position control mode (Pt or Pr mode) is usually used for the applications requiring precision positioning,
such as industry positioning machine, indexing table etc. Delta ASDA-AB series servo drive supports two
kinds of command sources in position control mode. One is an external pulse train (Pt: Position Terminals,
External Position Control) and the other is internal parameter (Pr: Position Register, i.e. internal parameters
P1-15 to P1-30, Internal Position Control). The external pulse train with direction which can control the
rotation angle of servo motor. The max. input frequency for the external pulse command is 500Kpps (Line
Driver) or 200Kpps (Open Collector) and it is equal to rotation speed of 3000r/min.
In order to provide a convenient position control function, Delta servo drive provides eight internal preset
parameters for position control. There are two setting methods of internal parameters, one is to set different
position command into these eight internal parameters before operation and then use POS0~POS2 of DI
signals of CN1 to perform positioning control. The other setting method is to use serial communication to
change the setting value of these eight internal parameters.
To make the servo motor and load operate more smoothly, Delta servo drive also provide complete Position
Spine Line (P-curve) profile for position control mode. For the closed-loop positioning, speed control loop is
the principal part and the auxiliary parameters are position loop gain and feed forward compensation. The
users can also select two kinds of tuning mode (Manual/Auto modes) to perform gain adjustment. This
Section 6.2 mainly describes the applicability of loop gain adjustment and feed forward compensation of
Delta servo system.
6.2.1 Command Source of Position (Pt) Control Mode
The command source of P mode is external pulse train input form terminals. There are three types of
pulse input and each pulse type is with
·
logic type (positive (+), negative (-)). They all can be set in
parameter P1-00. Please refer to the following relevant parameters:
P1 - 00
▲
PTT
External Pulse Input Type
Communication Addr.: 0100H
Default: 2
Related Section:
Applicable Control Mode: Pt
Section 6.2.1
Unit: N/A
Range: 0 ~ 132
Settings:
not used
A
B
C
•
Value A: Pulse type
A=0: AB phase pulse (4x)
A=1: CW + CCW pulse
A=2: Pulse + Direction
Содержание AC Servo Drive ASDA-AB
Страница 1: ......
Страница 13: ...Table of Contents ASDA AB Series Revision January 2009 This page intentionally left blank...
Страница 20: ...Chapter 1 Unpacking Check and Model Explanation ASDA AB Series Revision January 2009 1 7 110V models...
Страница 27: ...Chapter 3 Connections and Wiring ASDA AB Series 3 2 Revision January 2009 Figure 3 2 110V Servo Drive...
Страница 67: ...Chapter 3 Connections and Wiring ASDA AB Series 3 42 Revision January 2009 This page intentionally left blank...
Страница 85: ...Chapter 5 Trial Run and Tuning Procedure ASDA AB Series 5 8 Revision January 2009...
Страница 103: ...Chapter 5 Trial Run and Tuning Procedure ASDA AB Series 5 26 Revision January 2009 This page intentionally left blank...
Страница 149: ...Chapter 6 Control Modes of Operation ASDA AB Series 6 46 Revision January 2009 This page intentionally left blank...
Страница 246: ...Chapter 8 MODBUS Communications ASDA AB Series Revision January 2009 8 3 Cable Connection...
Страница 265: ...Chapter 9 Maintenance and Inspection ASDA AB Series 9 4 Revision January 2009 This page intentionally left blank...
Страница 275: ...Chapter 10 Troubleshooting ASDA AB Series 10 10 Revision January 2009 This page intentionally left blank...
Страница 282: ...Chapter 11 Specifications ASDA AB Series Revision January 2009 11 7 11 3 Servo Motor Speed Torque Curves...
Страница 307: ...Chapter 12 Application Examples ASDA AB Series 12 10 Revision January 2009...
Страница 333: ...Chapter 12 Application Examples ASDA AB Series 12 36 Revision January 2009 8 B A 2 5 Position SPEED Z pulse...
Страница 335: ...Chapter 12 Application Examples ASDA AB Series 12 38 Revision January 2009 Connecting to Delta DVP 01PU...
Страница 336: ...Chapter 12 Application Examples ASDA AB Series Revision January 2009 12 39 Connecting to Mitsubishi FX1PG...
Страница 337: ...Chapter 12 Application Examples ASDA AB Series 12 40 Revision January 2009 Connecting to Mitsubishi FX2N1PG...
Страница 338: ...Chapter 12 Application Examples ASDA AB Series Revision January 2009 12 41 Connecting to Mitsubishi AD75...
Страница 339: ...Chapter 12 Application Examples ASDA AB Series 12 42 Revision January 2009 This page intentionally left blank...
Страница 353: ...Appendix A Accessories ASDA AB Series A 14 Revision January 2009 This page intentionally left blank...
Страница 356: ...Appendix A Accessories ASDA AB Series Revision January 2009 B 3 Figure 1 Saddle on both ends Saddle on one end Figure 2...