The Aggregator also detects iSCSI storage devices on all interfaces and auto-configures to optimize
performance. Performance optimization operations, such as Jumbo frame size support, STP port-state
fast, and disabling of storm control on interfaces connected to an iSCSI storage device, are applied
automatically.
CLI configuration is necessary only when the configuration includes iSCSI storage devices that cannot
be automatically detected and when non-default QoS handling is required.
Link Aggregation
All uplink ports are configured in a single LAG (LAG 128). Server-facing ports are auto-configured as
part of link aggregation groups if the corresponding server is configured for LACP-based NIC teaming.
Static LAGs are not supported.
Tip
: The recommended LACP timeout is long-timeout mode.
Link Tracking
By default, all server-facing ports are tracked by the operational status of the uplink LAG. If the uplink
LAG goes down, the Aggregator loses its connectivity and is no longer operational; all server-facing
ports are brought down.
Tip
: If installed servers do not have connectivity to a ToR switch, check the Link Status LED of uplink
ports on the Aggregator. If all LEDs are ON, check the LACP configuration on the ToR switch that is
connected to the Aggregator to ensure the LACP is correctly configured.
VLANs
By default, all Aggregator ports belong to all 4094 VLANs and are members of untagged VLAN 1.
You can use the CLI or CMC interface to configure only the required VLANs on a port.
When you configure VLANs on server-facing interfaces (ports 1 to 32), you can assign VLANs to a
port or a range of ports by entering the vlan tagged or vlan untagged commands in interface
configuration mode; for example:
Uplink LAG
The tagged VLAN membership of the uplink LAG is automatically configured based on the VLAN
configuration of all server-facing ports (ports 1 to 32).
Note:
You can also use the CMC interface to configure VLANs.
FTOS(conf)# interface tengigabitethernet 0/2 - 4
FTOS(conf-if-range-te-0/2-4)# vlan tagged 5,7,10-12
FTOS(conf-if-range-te-0/2-4)# vlan untagged 3
Содержание PowerEdge M IO Aggregator
Страница 1: ...Dell PowerEdge FTOS Command Line Reference Guide for the M I O Aggregator Publication Date March 2013 ...
Страница 14: ...12 Before You Start w w w d e l l c o m s u p p o r t d e l l c o m ...
Страница 40: ...38 File Management w w w d e l l c o m s u p p o r t d e l l c o m ...
Страница 80: ...78 Control and Monitoring w w w d e l l c o m s u p p o r t d e l l c o m ...
Страница 90: ...88 u Boot w w w d e l l c o m s u p p o r t d e l l c o m ...
Страница 108: ...106 Data Center Bridging w w w d e l l c o m s u p p o r t d e l l c o m ...
Страница 114: ...112 Dynamic Host Configuration Protocol DHCP w w w d e l l c o m s u p p o r t d e l l c o m ...
Страница 128: ...126 Internet Group Management Protocol IGMP w w w d e l l c o m s u p p o r t d e l l c o m ...
Страница 162: ...160 Interfaces w w w d e l l c o m s u p p o r t d e l l c o m ...
Страница 178: ...176 IPv4 Routing w w w d e l l c o m s u p p o r t d e l l c o m ...
Страница 182: ...180 iSCSI Optimization w w w d e l l c o m s u p p o r t d e l l c o m ...
Страница 186: ...184 Link Aggregation Control Protocol LACP w w w d e l l c o m s u p p o r t d e l l c o m ...
Страница 190: ...188 Layer 2 w w w d e l l c o m s u p p o r t d e l l c o m ...
Страница 210: ...208 Security w w w d e l l c o m s u p p o r t d e l l c o m ...
Страница 222: ...220 Simple Network Management Protocol SNMP and Syslog w w w d e l l c o m s u p p o r t d e l l c o m ...
Страница 238: ...236 System Time w w w d e l l c o m s u p p o r t d e l l c o m Related Commands calendar set Sets the hardware clock ...
Страница 246: ...244 Uplink Failure Detection UFD w w w d e l l c o m s u p p o r t d e l l c o m ...
Страница 262: ...260 Debugging and Diagnostics w w w d e l l c o m s u p p o r t d e l l c o m ...