About Your System
19
Not a boot diskette
The operating system is trying to boot
from a diskette that does not have a
bootable operating system installed
on it.
Insert a diskette that has a bootable
operating system.
PCI BIOS failed to install
PCI device BIOS (Option ROM)
checksum failure is detected during
shadowing.
Ensure that all appropriate cables are
securely connected to the expansion
cards. If the problem persists, see
"Troubleshooting Expansion Cards" on
page 91.
PCIe Degraded Link Width
Error: Embedded
Bus#
nn
/Dev#
nn
/Func
n
Expected Link Width is
n
Actual Link Width is
n
Faulty or improperly installed PCIe
card.
Reseat the PCIe cards. See "Expansion
Cards" on page 63. If the problem
persists, see "Getting Help" on page 103.
PCIe Degraded Link Width
Error: Slot
n
Expected Link Width is
n
Actual Link Width is
n
Faulty or improperly installed PCIe
card in the specified slot number.
Reseat the PCIe card in the specified
slot number. See "Expansion Cards" on
page 63. If the problem persists, see
"Getting Help" on page 103.
PCIe Training Error:
Embedded
Bus#
nn
/Dev#
nn
/Func
n
Faulty or improperly installed PCIe
card.
Reseat the PCIe cards. See "Expansion
Cards" on page 63. If the problem
persists, see "Getting Help" on page 103.
PCIe Training Error:
Slot
n
Faulty or improperly installed PCIe
card in the specified slot number.
Reseat the PCIe card in the specified
slot number. See "Expansion Cards" on
page 63. If the problem persists, see
"Getting Help" on page 103.
Plug & Play Configuration
Error
Error encountered in initializing PCI
device; faulty system board.
Install the NVRAM_CLR jumper and
reboot the system. See Figure 6-1 for
jumper location. Check for a BIOS
update. If the problem persists, see
"Troubleshooting Expansion Cards" on
page 91. If the problem persists, see
"Getting Help" on page 103.
Primary drive 0/1
configuration error
Faulty drive. Parameters failure.
Ensure that the hard drive cables are
properly connected. See
"Troubleshooting a Hard Drive" on
page 90.
Table 1-4.
System Messages
(continued)
Message
Causes
Corrective Actions
Содержание PowerEdge 860
Страница 1: ...w w w d e l l c o m s u p p o r t d e l l c o m Dell PowerEdge 860 Systems Hardware Owner s Manual ...
Страница 8: ...8 Contents ...
Страница 28: ...28 About Your System ...
Страница 42: ...42 Using the System Setup Program ...
Страница 78: ...78 Installing System Components ...
Страница 102: ...102 Jumpers and Connectors ...
Страница 136: ...136 Glossary ...