![Dell PowerConnect J-8216 Скачать руководство пользователя страница 107](http://html.mh-extra.com/html/dell/powerconnect-j-8216/powerconnect-j-8216_hardware-manual_84539107.webp)
NOTE:
We recommend that you maintain N +1 or N+N power supplies in your
switch at all times. Replace failed power supplies immediately to prevent
unexpected failures.
Power management raises a minor alarm if the number of online power
supplies in your switch is less than the number required to maintain the
configured power redundancy (N+1 or N+N). If the problem is not corrected
in 5 minutes, a major alarm is issued.
Power management raises a major alarm if the number of online power
supplies in your switch is less than N power supplies. Power management
provides power to line cards in priority order until power is exhausted. The
remaining line cards are powered off.
If a new line card is installed in an operational switch, power management
does not power on the line card if the increased power demand exceeds the
total available power, including redundant power. If redundant power is used
to power on the line card, a minor alarm is raised, which becomes a major
alarm in 5 minutes if the condition is not corrected.
Related
Documentation
AC Power Supply in a J-EX8200 Switch on page 39
•
•
Understanding Power Management on J-EX Series Switches
Calculating the J-EX8200 Switch Fiber-Optic Cable Power Budget
Calculate the link's power budget when planning fiber-optic cable layout and distances
to ensure that fiber-optic connections have sufficient power for correct operation. The
power budget is the maximum amount of power the link can transmit. When you calculate
the power budget, you use a worst-case analysis to provide a margin of error, even though
all the parts of an actual system do not operate at the worst-case levels.
To calculate the worst-case estimate for fiber-optic cable power budget (
P
B
) for the
link:
1.
Determine values for the link's minimum transmitter power (
P
T
) and minimum receiver
sensitivity (
P
R
). For example, here, (
P
T
) and (
P
R
) are measured in decibels, and
decibels are referred to one milliwatt (dBm).
P
T
= –15 dBm
P
R
= –28 dBm
NOTE:
See the specifications for your transmitter and receiver to find the
minimum transmitter power and minimum receiver sensitivity.
2.
Calculate the power budget (
P
B
) by subtracting (
P
R
) from (
P
T
):
91
Chapter 7: Planning Power Requirements
Содержание PowerConnect J-8216
Страница 1: ...Dell PowerConnect J Series J EX8216 Ethernet Switch Hardware Guide Published 2010 10 05 ...
Страница 6: ...vi ...
Страница 16: ...xvi Dell PowerConnect J Series J EX8216 Ethernet Switch Hardware Guide ...
Страница 18: ...2 Dell PowerConnect J Series J EX8216 Ethernet Switch Hardware Guide ...
Страница 78: ...62 Dell PowerConnect J Series J EX8216 Ethernet Switch Hardware Guide ...
Страница 84: ...68 Dell PowerConnect J Series J EX8216 Ethernet Switch Hardware Guide ...
Страница 92: ...76 Dell PowerConnect J Series J EX8216 Ethernet Switch Hardware Guide ...
Страница 96: ...80 Dell PowerConnect J Series J EX8216 Ethernet Switch Hardware Guide ...
Страница 110: ...94 Dell PowerConnect J Series J EX8216 Ethernet Switch Hardware Guide ...
Страница 112: ...96 Dell PowerConnect J Series J EX8216 Ethernet Switch Hardware Guide ...
Страница 158: ...142 Dell PowerConnect J Series J EX8216 Ethernet Switch Hardware Guide ...
Страница 164: ...148 Dell PowerConnect J Series J EX8216 Ethernet Switch Hardware Guide ...
Страница 166: ...150 Dell PowerConnect J Series J EX8216 Ethernet Switch Hardware Guide ...
Страница 172: ...156 Dell PowerConnect J Series J EX8216 Ethernet Switch Hardware Guide ...
Страница 189: ...PART 5 Switch and Component Maintenance Routine Maintenance on page 175 173 ...
Страница 190: ...174 Dell PowerConnect J Series J EX8216 Ethernet Switch Hardware Guide ...
Страница 197: ...PART 6 Returning Hardware Getting Help on page 183 181 ...
Страница 198: ...182 Dell PowerConnect J Series J EX8216 Ethernet Switch Hardware Guide ...
Страница 216: ...200 Dell PowerConnect J Series J EX8216 Ethernet Switch Hardware Guide ...
Страница 228: ...212 Dell PowerConnect J Series J EX8216 Ethernet Switch Hardware Guide ...
Страница 244: ...228 Dell PowerConnect J Series J EX8216 Ethernet Switch Hardware Guide ...
Страница 252: ...236 Dell PowerConnect J Series J EX8216 Ethernet Switch Hardware Guide ...
Страница 253: ...PART 8 Compliance Information Compliance Information on page 239 237 ...
Страница 254: ...238 Dell PowerConnect J Series J EX8216 Ethernet Switch Hardware Guide ...
Страница 259: ...Declarations of Conformity for J EX8216 Switches 243 Chapter 20 Compliance Information ...
Страница 261: ...PART 9 Index Index on page 247 245 ...
Страница 262: ...246 Dell PowerConnect J Series J EX8216 Ethernet Switch Hardware Guide ...
Страница 270: ...254 Dell PowerConnect J Series J EX8216 Ethernet Switch Hardware Guide ...