148
Troubleshooting
Linux Operating System Errors
Table 9-7 describes issues related to the Linux operating system.
Table 9-7. Linux Operating System Errors
Error Message
Corrective Action
<Date:Time> <HostName>
kernel: sdb: asking for
cache data failed
<Date:Time> <HostName>
kernel: sdb: assuming
drive cache: write
through
This error message is displayed when the Linux
Small Computer System Interface (SCSI)
mid-layer asks for physical disk cache settings.
The controller firmware manages the virtual disk
cache settings on a per controller and a per
virtual disk basis, so the firmware does not
respond to this command. The Linux SCSI
mid-layer assumes that the virtual disk's cache
policy is
Write-Through
. SDB is the device node
for a virtual disk. This value changes for each
virtual disk.
See the section "Physical Disk Management" on
page 108 for more information about
Write-Through
cache.
Except for this message, there is no effect of this
behavior on normal operation. The cache policy
of the virtual disk and the I/O throughput are
not affected by this message. The cache policy
settings for the PERC H700 and PERC H800
SAS RAID system remain unchanged.
PERC7.2_UG.book Page 148 Thursday, March 3, 2011 2:14 PM
Содержание PERC H700
Страница 1: ...Dell PowerEdge RAID Controller PERC H700 and H800 User s Guide ...
Страница 10: ...10 Contents ...
Страница 14: ...14 Safety Instructions ...
Страница 40: ...40 Storage Controller Features ...
Страница 68: ...68 Installing and Configuring Hardware ...
Страница 120: ...120 CacheCade ...
Страница 130: ...130 Security Key and RAID Management ...
Страница 152: ...152 Troubleshooting ...
Страница 154: ...154 Regulatory Notices ...
Страница 156: ...156 Corporate Contact Details Taiwan Only ...
Страница 178: ...178 Index ...