Troubleshooting
147
Replace Member Errors
Table 9-6 describes issues related to the
Replace Member
feature.
NOTE:
For more information about the Replace Member features, see
"Using
Replace Member and Revertible Hot Spares" on page 35.
Table 9-6. Replace Member Operation Errors
Issue
Corrective Action
The source disk fails
during the
Replace
Member
operation.
If the source data is available from other disks in the virtual
disk, the rebuild begins automatically on the target disk, using
the data from the other disks.
Target disk fails
If the target disk fails, the
Replace Member
operation aborts.
Other disks fail
If the target disk fails and the
Replace Member
operation
aborts but the source data is still available, then the
Replace
Member
operation continues as
Replace Member
.
PERC7.2_UG.book Page 147 Thursday, March 3, 2011 2:14 PM