86
Configuring and Managing RAID
When you define the virtual disks, you can set the following virtual disk
parameters:
• RAID level
• Stripe element size
• Read policy
• Write policy
• Type of initialization
• Hot spare configuration
NOTE:
The default hard drive cache policy for a virtual disk composed with SAS
hard drives is
disabled
and with SATA hard drives is
enabled
. The Virtual Disk
parameter can not be changed in the BIOS configuration Utility.
Table 6-2 shows the parameters that you can configure when defining
virtual disks.
Table 6-2. Virtual Disk Parameters and Descriptions
Parameter
Description
RAID Level RAID Level
specifies whether the virtual disk is RAID 0, 1, 5, 6, 10,
50, or 60. The number of disks, disk capacity, the requirements for
fault tolerance, performance, and capacity should be considered when
selecting the RAID level. For more information, see "Summary of
RAID Levels" on page 17.
Stripe
Element Size
Stripe Element Size
specifies the size of the segments written to each
physical disk in a RAID 0, 1, 5, 6, 10, 50, and 60 virtual disk. You can
set the stripe element size to 8 KB, 16 KB, 32 KB, 64 KB, 128 KB,
256 KB, 512 KB, or 1024 KB. The default and recommended stripe
element size is 64 KB.
A larger stripe element size provides better read performance if your
system mostly does sequential reads.
PERC7.2_UG.book Page 86 Thursday, March 3, 2011 2:14 PM
Содержание PERC H700
Страница 1: ...Dell PowerEdge RAID Controller PERC H700 and H800 User s Guide ...
Страница 10: ...10 Contents ...
Страница 14: ...14 Safety Instructions ...
Страница 40: ...40 Storage Controller Features ...
Страница 68: ...68 Installing and Configuring Hardware ...
Страница 120: ...120 CacheCade ...
Страница 130: ...130 Security Key and RAID Management ...
Страница 152: ...152 Troubleshooting ...
Страница 154: ...154 Regulatory Notices ...
Страница 156: ...156 Corporate Contact Details Taiwan Only ...
Страница 178: ...178 Index ...