Configuring and Managing RAID
87
Write Policy Write Policy
specifies the controller write policy. You can set the write
policy to
Write-Back
or
Write-Through
.
In
Write-Back
caching, the controller sends a data transfer
completion signal to the host when the controller cache has received
all the data in a transaction.
NOTE:
If a Battery Backup Unit (BBU) is present, the default cache
setting is Write-Back. If no BBU is present, the default cache policy
default setting is Write-Through.
NOTE:
If Write-Back is enabled and the system is quickly turned off and
then on, the controller may pause as the system flushes cache memory.
Controllers that contain a battery backup default to Write-Back caching.
In
Write-Through
caching, the controller sends a data transfer
completion signal to the host when the disk subsystem has received
all the data in a transaction.
Read Policy
Read-Ahead
enables the read ahead feature for the virtual disk.
You can set the parameter to
Read-Ahead
,
No-Read-Ahead
,
or
Adaptive
. The default is
Adaptive-Read-Ahead
.
Read-Ahead
specifies that the controller uses
Read-Ahead
for the
current virtual disk.
Read-Ahead
capability allows the controller to
read sequentially ahead of requested data and store the additional
data in cache memory, anticipating that the data is required soon.
No-Read-Ahead
specifies that the controller does not use read ahead
for the current virtual disk.
Adaptive
specifies that the controller begins using
Read-Ahead
if the
two most recent disk accesses occurred in sequential sectors.
If all read requests are random, the algorithm reverts to
No-Read-Ahead
; however, all requests are still evaluated for
possible sequential operation.
Table 6-2. Virtual Disk Parameters and Descriptions
(continued)
Parameter
Description
PERC7.2_UG.book Page 87 Thursday, March 3, 2011 2:14 PM
Содержание PERC H700
Страница 1: ...Dell PowerEdge RAID Controller PERC H700 and H800 User s Guide ...
Страница 10: ...10 Contents ...
Страница 14: ...14 Safety Instructions ...
Страница 40: ...40 Storage Controller Features ...
Страница 68: ...68 Installing and Configuring Hardware ...
Страница 120: ...120 CacheCade ...
Страница 130: ...130 Security Key and RAID Management ...
Страница 152: ...152 Troubleshooting ...
Страница 154: ...154 Regulatory Notices ...
Страница 156: ...156 Corporate Contact Details Taiwan Only ...
Страница 178: ...178 Index ...