106
Configuring and Managing RAID
Physical Disk Actions
Table 6-6 describes the actions you can perform on physical disks.
For procedures that can be used to perform the actions, see "Physical Disk
Management" on page 108.
Rebuild
Select
Rebuild
to rebuild one or more failed physical disks. For information
on performing a physical disk rebuild, see "Performing a Manual Rebuild of an
Individual Physical Disk" on page 111.
Several of the controller configuration settings and the virtual disk settings
affect the actual rate of rebuild. The factors include the rebuild rate setting,
virtual disk stripe size, virtual disk read policy, virtual disk write policy, and the
amount of workload placed on the storage subsystem. For information on
getting the best rebuild performance from your RAID controller, see the
documentation on Dell Support website at
support.dell.com/manuals
.
Table 6-6. Physical Disk Actions
Action
Description
Rebuild
Regenerates all data to a replacement disk in a redundant
virtual disk (RAID level 1, 5, 6, 10, 50, or 60) after a disk
failure. A disk rebuild normally occurs without interrupting
normal operations on the affected virtual disk.
Replace Member
Replaces the disk in the virtual disk with another disk that can
be selected.
LED Blinking
Indicates when physical disks are being used to create a virtual
disk. You can choose to start or stop the LED blinking.
Force Online
Changes the state of the selected physical disk to online.
Force Offline
Changes the state of the selected physical disk so that it is no
longer part of a virtual disk.
Make Global HS
Designates the selected physical disk as a global hot spare.
A global hot spare is part of a pool for all virtual disks
controlled by the controller.
Designates the selected physical disk as a global hot spare.
Remove HS
Removes a dedicated hot spare from its disk group or a global
hot spare from the global pool of hot spares.
PERC7.2_UG.book Page 106 Thursday, March 3, 2011 2:14 PM
Содержание PERC H700
Страница 1: ...Dell PowerEdge RAID Controller PERC H700 and H800 User s Guide ...
Страница 10: ...10 Contents ...
Страница 14: ...14 Safety Instructions ...
Страница 40: ...40 Storage Controller Features ...
Страница 68: ...68 Installing and Configuring Hardware ...
Страница 120: ...120 CacheCade ...
Страница 130: ...130 Security Key and RAID Management ...
Страница 152: ...152 Troubleshooting ...
Страница 154: ...154 Regulatory Notices ...
Страница 156: ...156 Corporate Contact Details Taiwan Only ...
Страница 178: ...178 Index ...