119
reconfigures and adjusts its size to reflect the addition of the member SSD.
The number of SSDs to be removed from a CacheCade virtual disk cannot
equal the total number of SSDs currently in the CacheCade virtual disk.
After the automatic reconfiguration and resizing of a CacheCade virtual disk,
the new virtual disk size is displayed in both the BIOS configuration utility as
well as in the OpenManage storage management application.
CAUTION:
If a disk is removed from a CacheCade virtual disk, the associated slot
for that disk is a hot slot for the CacheCade volume. Any compatible disk inserted
into that slot is automatically added to the CacheCade virtual disk. Any pre-
existing data on that drive is lost.
NOTE:
Disks inserted into a CacheCade hot slot must be equal to or greater than
the smallest contributing disk in the virtual disk.
Manual Resizing of CacheCade Virtual Disks
In operating system management applications, a manual resizing of a
CacheCade virtual disk occurs due to the addition or removal of drives.
Reboot is not be necessary.
• Any number of SSDs can be added to a CacheCade virtual disk.
• There is no SAS and SATA mixing allowed within a CacheCade virtual
disk, so SATA SSDs cannot be added to a SAS CacheCade virtual disk and
vice versa.
• HDDs cannot be added to a CacheCade virtual disk.
NOTE:
Capacity of drives added to a CacheCade volume must be equal to or
greater than the smallest contributing drive in the virtual disk. The manual resizing
of a CacheCade virtual disk cannot be initiated in the BIOS configuration utility. It
can only be initiated in the OpenManage storage management application.
PERC7.2_UG.book Page 119 Thursday, March 3, 2011 2:14 PM
Содержание PERC H700
Страница 1: ...Dell PowerEdge RAID Controller PERC H700 and H800 User s Guide ...
Страница 10: ...10 Contents ...
Страница 14: ...14 Safety Instructions ...
Страница 40: ...40 Storage Controller Features ...
Страница 68: ...68 Installing and Configuring Hardware ...
Страница 120: ...120 CacheCade ...
Страница 130: ...130 Security Key and RAID Management ...
Страница 152: ...152 Troubleshooting ...
Страница 154: ...154 Regulatory Notices ...
Страница 156: ...156 Corporate Contact Details Taiwan Only ...
Страница 178: ...178 Index ...