Troubleshooting and problem solving
These procedures are intended to be used only during initial configuration for verifying that hardware setup is successful. They are not
intended to be used as troubleshooting procedures for configured systems using production data and I/O.
NOTE:
For further troubleshooting help after setup, and when data is present, see
Topics:
•
•
•
Locate the service tag
ME4 Series storage systems are identified by a unique Service Tag and Express Service Code.
The Service Tag and Express Service Code can be found on the front of the system by pulling out the information tag. Alternatively, the
information might be on a sticker on the back of the storage system chassis. This information is used to route support calls to appropriate
personnel.
Operators (Ops) panel LEDs
Each ME4 Series enclosure features an Operators (Ops) panel located on the chassis left ear flange. This section describes the Ops panel
for 2U and 5U enclosures.
2U enclosure Ops panel
The front of the enclosure has an Ops panel that is located on the left ear flange of the 2U chassis.
The Ops panel is a part of the enclosure chassis, but is not replaceable on-site.
The Ops panel provides the functions that are shown in the following figure and listed in
Table 9. Ops panel functions—2U enclosure front
.
Figure 30. Ops panel LEDs—2U enclosure front panel
Table 9. Ops panel functions—2U enclosure front panel
No.
Indicator
Status
1
System power
Constant green: at least one PCM is supplying power
Off: system not operating regardless of AC present
2
Status/Health
Constant blue: system is powered on and controller is ready
8