![Dell EMC ME4 Series Скачать руководство пользователя страница 42](http://html1.mh-extra.com/html/dell-emc/me4-series/me4-series_deployment-manual_2468360042.webp)
Format volumes on the Windows server
Perform the following steps to format a volume on a Windows server:
1. Open Server Manager.
2. Select
Tools
>
Computer Management
.
3. Right-click on
Disk Management
and select
Rescan Disks
.
4. Right-click on the new disk and select
Online
.
5. Right-click on the new disk again select
Initialize Disk
.
The
Initialize Disk
dialog box opens.
6. Select the partition style for the disk and click
OK
.
7. Right-click on the unallocated space, select the type of volume to create, and follow the steps in the wizard to create the volume.
iSCSI host server configuration for Windows Server
These instructions document IPv4 configuration with dual switch subnet for network redundancy and failover. These instructions do not
cover IPv6 configuration:
Prerequisites
•
Complete the ME Storage Manager guided setup process and storage setup process.
•
Refer to the cabling diagrams within this guide before attaching a host to the storage system; careful planning ensures a successful
deployment.
•
Complete a planning worksheet with the iSCSI network IP addresses to be used, per the example in the following table:
Table 6. Example worksheet for host server with dual port iSCSI NICs
Management
IP
Server Management
10.10.96.46
ME4024Controller A Management
10.10.96.128
ME4024 Controller B Management
10.10.96.129
Subnet 1
Server iSCSI NIC 1
172.1.96.46
ME4024 controller A port 0
172.1.100.128
ME4024 controller B port 0
172.1.200.129
ME4024 controller A port 2
172.1.102.128
ME4024 controller B port 2
172.1.202.129
Subnet Mask
255.255.0.0
Subnet 2
Server iSCSI NIC 1
172.2.96.46
ME4024 controller A port 1
172.2.101.128
ME4024 controller B port 1
172.2.201.129
ME4024 controller A port 3
172.2.103.128
ME4024 controller B port 3
172.3.203.129
Subnet Mask
255.255.0.0
NOTE:
The following instructions document IPv4 configurations with a dual switch subnet for network redundancy and
failover. It does not cover IPv6 configuration.
Attach iSCSI hosts to the storage system
Perform the following steps to attach iSCSI hosts to the storage system:
42
Perform host setup