background image

37 

DESIGNED SECURITY INC       

800-272-3555            www.dsigo.com  

1402 Hawthorne Street   Bastrop, Texas 78602         Fax 512 321 9181   

Email: [email protected]

 

INS8300 

Congratulations on your purchase of a DSI Optical Turnstile system. 

 

This guide provides information for cleaning and maintaining the finishes, materials and optical paths of DSI’s standard 

finishes on our turnstile line.  Including ES810, ES811, ES831, ES880, ES8300, ES840, ES850, and ES860   

 

DSI recommends the following information be distributed to appropriate personnel to preserve long lasting appearance of 

the finish, and to maintain clear optical paths for the Infrared beams. 

 

Stainless Steel - 

CAUTION: Avoid getting polish or solvents on the Plexiglas panels to prevent  

      contaminating the optical path.

 

The suggested polish is a light household polish/oil.   
Holloway House Lemon Oil is what we use at the factory.

 

http://www.hollowayhouse.net 

 

 

Soap and water may be used to clean stains, then use polish to preserve the finish. 

 

Corian and Laminates-  

 

Soapy water or ammonia-based cleaners will remove most dirt and stains from Corian and Laminate finishes. 
Additional Corian information is available from the DuPont Corian website: 

 

http://www.corian.com

 

 

Brass -  

These finishes are clear-coated and should be polished with any product labeled as appropriate for a clear-coat 

finish.  Automotive clear-coat polishes work well for this application.   (Turtle Wax’s Clear Coat Polish and Restorer 

is what we use at the factory) 

Powder Coat Painted - 

Clean with mild soap, water and a soft non-abrasive cloth.  A periodic use of a non-ammonia based cleaning 

solution (Formula 409) can be used for oils or stubborn stains.  Always apply by hand using a circular motion. 

 

Plexiglas - 

CAUTION: Never use ammonia-based glass cleaners, abrasive cleaners, or paper towels to clean  

      Plexiglas.

 

These surfaces should be cleaned with a soft cloth dampened with soap and water, or use a spray cleaner such as 
Chemtronics® ES1668; at

 

http://www.chemtronics.com/

 or you may call Chemtronics at 800-645-5244 

for more information.  

Optics -

 

The Plexiglas over the sensors and reflectors must be kept optically clear for the Infrared Beams to 

function properly.  Cleaning personnel need to be instructed to avoid wiping any oils or other polishes on these 

panels.  Use of alcohol or ammonia based cleaners may leave a static charge which will attract dust, the 

Chemtronics® ES1668 is an anti-static cleaner that works well.  Any similar anti-static cleaner approved for use on 

Plexiglas should work. 

Dust accumulation on the inside of these Plexiglas panels, and on the Sensors/Reflectors themselves, can impair 

the optical path which may lead to false alarms.  A periodic inspection after initial installation may help determine 

the appropriate interval for cleaning the inside surfaces, based upon the environment at the site.

 

CARE AND CLEANING 

Содержание DSI ES8300

Страница 1: ...ES8300 ACRYLIC BARRIER OPTICAL TURNSTILE INSTALLATION AND OPERATION INSTRUCTIONS...

Страница 2: ......

Страница 3: ...3 DESIGNED SECURITY INC 800 272 3555 www dsigo com 1402 Hawthorne Street Bastrop Texas 78602 Fax 512 321 9181 Email dsi dsigo com INS8300 CUSTOM NOTES...

Страница 4: ......

Страница 5: ...5 DESIGNED SECURITY INC 800 272 3555 www dsigo com 1402 Hawthorne Street Bastrop Texas 78602 Fax 512 321 9181 Email dsi dsigo com INS8300 SITE PREPARATION...

Страница 6: ......

Страница 7: ...straight forward installation when a little time is taken to prepare before you begin You may choose to take the time now to read and understand the installation and operation instructions in order t...

Страница 8: ......

Страница 9: ...9 DESIGNED SECURITY INC 800 272 3555 www dsigo com 1402 Hawthorne Street Bastrop Texas 78602 Fax 512 321 9181 Email dsi dsigo com INS8300 INSTALLATION...

Страница 10: ......

Страница 11: ...be taken in placing the bollards to ensure that the user may easily access the Reader System I E Mag Card Proximity Biometric etc provided by installer integrator while maintaining a reasonable flow...

Страница 12: ...ds is shown to help installers understand the proper placement of the Turnstiles in reference to the direction of traffic When entering the lane from the Secure side or Exit Side the Electronics Packa...

Страница 13: ...ng finish or creating a hazard to pedestrian traffic PANEL INSTALLATION STEPS Place panel on Hinge Points Tilt into place in Bollard Insert T Handle Hex key wrench into small hole near the top side ed...

Страница 14: ...can calculate the length of the long side C of any right angle triangle based upon the known length of the other two sides Use this device to verify alignment by referencing a chalk line on the floor...

Страница 15: ...N ENCODER BARRIER PANEL D SENSORS C SENSORS B A SENSORS MOTOR ELECTRONICS PACKAGE MOUNTING POINTS CABLE ACCESS MOUNTING POINTS CABLE ACCESS END VIEW B SIDE SHOWN The A Side of each Bollard will have e...

Страница 16: ...C Output Default Jumper covers upper and center pins for N O Output SET TRIMMERS setting of 10 1 second To reach top menu press M key 3 times Use down arrow to highlight 3 Trimmers Press Return Displ...

Страница 17: ...ve to allow a user to exit from the secure side although the barriers may always be pushed open in an emergency The D1 2 3 Sensors work similarly for users exiting from the secure side IE blocking thi...

Страница 18: ...el Below the Encoder is the Barrier Panel Located on the same shaft Units with optional Locking will have Locking Solenoid hardware mounted on this shaft This shaft goes into a shaft Coupler that allo...

Страница 19: ...WIRING...

Страница 20: ...lard when facing from the Entrance un secure side This bollard should have the Electronics Package in the side facing into the lane Leave adequate service loop in cables Route cables neatly in pedesta...

Страница 21: ...op Texas 78602 Fax 512 321 9181 Email dsi dsigo com INS8300 ENCODER 2 CONNECTOR DETAIL MOTOR 2 CONNECTOR DETAIL PIN COLOR 1 Shield 2 Black 3 Vacant 4 Red 5 White 6 Green PIN COLOR 1 White 2 Black 3 Sh...

Страница 22: ...sure which stows barriers N O Free Exit 15 16 Dry contact closure enables the Free Exit function N O Emergency 17 18 Dry contact closure moves Barriers to Exit activates alarm graphics and alarm relay...

Страница 23: ...p over long cable run from Power Supply may create a high current condition that trips the breaker Use appropriate gauge wire for your installation LIGHT ARRAY CONNECTIONS Entry local and Exit adjacen...

Страница 24: ......

Страница 25: ...SETUP OPERATION...

Страница 26: ......

Страница 27: ...e the one you are aiming for Primarily on A and B Sensors Adjust Sensor bracket for a good signal lock LED Off indicates the Sensor is in alignment with the Reflector and in a stable operating state L...

Страница 28: ...OR O O EXIT CARD O OR O O INVALID CARD O O O RESET BYPASS O O ENTRY CLOSED O EXIT CLOSED O ARM DISABLE O FREE EXIT EXIT WHEN D SENSOR IS BROKEN BY USER EMERGENCY O O VOICE ENABLE HORN DISABLE SILENT...

Страница 29: ...AY SOUND MOVE THROUGH THE LANE PROMPTLY Avoid stopping or moving backward as this will trigger the alarm TIP During passage through the lane swinging items purses briefcases etc could be interpreted b...

Страница 30: ...THEY SHOULD VISIT THE GUARD NOTE The single most frequent violation and cause of abuse results from Users pushing through the barriers It is important that the User be trained to NEVER touch the barr...

Страница 31: ...31 DESIGNED SECURITY INC 800 272 3555 www dsigo com 1402 Hawthorne Street Bastrop Texas 78602 Fax 512 321 9181 Email dsi dsigo com INS8300 APPENDIX...

Страница 32: ......

Страница 33: ...may optionally be N C see Page 16 N O Dry Contact for Alarm N O Dry Contact for Time Out N O Dry Contact for Valid Passage N O Dry Contact for Bypass N O Dry Contact for Invalid Card Accessory Power 1...

Страница 34: ...e in feet of actual Wire Run from power supply to the most remote load 125 Multiply figures from above two lines Match final number to Table below to determine Wire Gauge needed to provide adequate Vo...

Страница 35: ...ouble calls Pull Doors It is a good idea not to place the bollards immediately before a pull door The action of pulling the door open may cause the user to back into the lane This could generate a nui...

Страница 36: ...ay would be ideal Slowing traffic through the lanes minimizes false alarms generated through beam interruption by briefcases bags umbrellas coats etc A rapidly moving user could be swinging these item...

Страница 37: ...Automotive clear coat polishes work well for this application Turtle Wax s Clear Coat Polish and Restorer is what we use at the factory Powder Coat Painted Clean with mild soap water and a soft non ab...

Страница 38: ...a larger gauge smaller number or increase the Supply Voltage in order to deliver 24 VDC at the Power Input Connector while the ES8300 is operating under load Symptom Numerous False Alarms These Alarms...

Страница 39: ...nstalled used and maintained according to instructions DSI will for a period of three 3 years from date of purchase repair or replace any part which upon our examination proves to be defective under n...

Отзывы: