22
DESIGNED SECURITY INC
800-272-3555 www.dsigo.com
1402 Hawthorne Street Bastrop, Texas 78602 Fax 512 321 9181
Email: [email protected]
INS8300
INPUT AND OUTPUT CONNECTION REQUIREMENTS
Inputs from Access Control System include:
Entry Valid Card Read
1-2
Dry contact closure indicating valid Entry card read
(Momentary Closure of .5 Second or Less recommended)
N/O
Exit Valid Card Read
3-4
Dry contact closure indicating valid Exit card read
(Momentary Closure of .5 Second or Less recommended)
N/O
Invalid Card
5-6
Dry contact closure when an invalid card has been presented.
N/O
Inputs for Remote Control include:
Reset/Bypass
7-8
Dry contact closure to reset alarms or to bypass the lane, stow
the barriers and allow unrestricted traffic flow.
N/O
Entry Closed
9-10
Dry contact closure disables Entry mode.
N/O
Exit Closed
11-12
Dry contact closure disables Exit mode.
N/O
Arm Disable
13-14
Dry contact closure which stows barriers.
N/O
Free Exit
15-16
Dry contact closure enables the “Free Exit” function.
N/O
Emergency
17-18
Dry contact closure, moves Barriers to Exit, activates alarm
graphics, and alarm relay output.
N/O
Voice Enable/
Horn Disable
19-20
Dry contact closure, only on models with Voice Annunciation
Option. Disables Alarm horn when shorted.
N/O
Outputs for Remote Monitoring include:
Alarm
1-2
Indicates that unit is in Alarm Mode.
N/O*
Timeout
3-4
Indicates that the valid read timed out before passage was
completed. Closes for .3 sec when triggered.
N/O*
Valid Passage
5-6
Indicates that a passage was completed. Closes for .3 sec when
triggered.
N/O*
Bypass
7-8
Indicates when unit is in Bypass Mode.
N/O*
Invalid Card
9-10
Indicates an Invalid Card input has occurred.
N/O*
+/- 12 Volt DC
11-12
Accessory 12 VDC Max Current 2 Amps
* Default.
(N/C Outputs available via Jumper Setting. See page 16 for detail)
WARNING:
Multiple lanes sharing a common Input Source must be isolated through a unique relay contact
for each lane input. Wiring common inputs in a daisy-chain (parallel) can cause damage to electronics.
Содержание DSI ES8300
Страница 1: ...ES8300 ACRYLIC BARRIER OPTICAL TURNSTILE INSTALLATION AND OPERATION INSTRUCTIONS...
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 8: ......
Страница 10: ......
Страница 19: ...WIRING...
Страница 24: ......
Страница 25: ...SETUP OPERATION...
Страница 26: ......
Страница 32: ......