28
DESIGNED SECURITY INC
800-272-3555 www.dsigo.com
1402 Hawthorne Street Bastrop, Texas 78602 Fax 512 321 9181
Email: [email protected]
INS8300
FINAL TESTING PROCEDURE
Provide Input or State from Left Column, Look for responses marked with
O
INPUTS
OUTPUTS
BARRIER
POSITION
ALARM TIMEOUT
VALID
PASSAGE BYPASS
INVALID
CARD AUDIBLE ENTRY EXIT CLOSED
ENTRY CARD
O
OR
O
O
EXIT CARD
O
OR
O
O
INVALID CARD
O
O
O
RESET/BYPASS
O
O
ENTRY CLOSED
O
EXIT CLOSED
O
ARM DISABLE
O
FREE EXIT
EXIT WHEN “D” SENSOR
IS BROKEN BY USER
EMERGENCY
O
O
VOICE ENABLE/HORN
DISABLE
SILENT WHEN IN ALARM
BARRIER AND SENSOR STATES
FORCED
ARM
& PASSAGE
O
O
BARRIERS WILL
PROVIDE RESISTANCE
AGAINST ATTEMPTS TO
FORCE PASSAGE
NO
PASSAGE
TAILGATE
O
O
WARNING:
Multiple lanes sharing a common Input Source must be isolated through a unique relay contact
for each lane input. Wiring common inputs in a daisy-chain (parallel) can cause damage to electronics.
Содержание DSI ES8300
Страница 1: ...ES8300 ACRYLIC BARRIER OPTICAL TURNSTILE INSTALLATION AND OPERATION INSTRUCTIONS...
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 8: ......
Страница 10: ......
Страница 19: ...WIRING...
Страница 24: ......
Страница 25: ...SETUP OPERATION...
Страница 26: ......
Страница 32: ......