background image

29 

DESIGNED SECURITY INC       

800-272-3555            www.dsigo.com  

1402 Hawthorne Street   Bastrop, Texas 78602         Fax 512 321 9181   

Email: [email protected]

 

INS8300 

GUIDELINES FOR EVERYDAY USE 

(PROVIDE COPIES TO ALL TURNSTILE USERS) 

 

Optical Turnstiles are provided for greater security in your workplace.   

They help ensure that only authorized individuals will be allowed into the secure areas of your facility.   

You may find daily use of Optical Turnstiles becomes routine as you follow these basic guidelines: 

 

USER VALIDATION

  

“ID”  for access control can be of many types, from card readers to biometric systems.   

Please refer to instructions provided for reader operation by the manufacturer, or by your security director.  

 

 

Look  at  DISPLAY 

 status, then

  PRESENT  ID

 to 

the  Reader  mounted  on,  or  in,  the  right-hand 

bollard of the lane you are using.  It may beep to 

indicate your ID was read.  

 

 

Listen

  for  a 

BEEP

  after  the 

ID  has  been 

validated

 and/or 

watch

 the Display on the top of 

the right-hand bollard to indicate authorization.   

 

 

Next 

Look

 for a 

PROCEED 

 message to indicate 

that 

you are now authorized

 to pass through the 

lane.  

The barriers will automatically swing out

of the way

 allowing passage.   

 

CAUTION: 

AVOID TOUCHING THE BARRIER

, except in an Emergency, otherwise 

AN ALARM MAY SOUND

 

 

 

MOVE THROUGH THE LANE PROMPTLY.

  Avoid stopping or moving backward, as this will trigger the alarm. 

 

TIP: 

During passage through the lane, swinging items (purses, briefcases, etc) could be interpreted by the turnstile 

as a person tailgating you, or moving in the other direction, thus causing an alarm.   To avoid delays caused by 

false alarms, hold items high and close to your body, or at your side as you pass through the lane. 

 

 

IF ALARM SOUNDS

, exit the lane, 

STOP

 and wait for security personnel to respond. 

 

 

Once through the lane, continue moving ahead to clear the lane for other users. 

 

FREE EXIT MODE 

Some turnstiles may be configured for “Free-Exit,” meaning there is no requirement to present ID when leaving the secured 

area.  Look for 

PROCEED/BYPASS 

graphic on the right-hand side of the lanes when in Free-exit mode.   

 

 

As  you  enter  the  lane,

 

the  turnstile  will  sense  your  presence  and  direction 

 allowing  you  to  exit the 

secured area of the building.  

Barriers will automatically open for Free Exit. 

  Pass through turnstile as 

outlined above.   

 

 

Keep in mind that the sensors are active during Free-exit mode.  Keep any bags or packages high and close to 

your body, or at your side, and avoid swinging them, as this may cause an alarm, even in Free Exit mode. 

 

EMERGENCY USE 

 

 

During  an  emergency  you  may  push  through  the  Acrylic  Barriers.  Follow  established  procedure  for 

emergency egress of the building. 

DISPLAY GRAPHICS 

 

 

 

 

 

 

 

 

      LANE READY       PROCEED           ALARM             CLOSED 

                                   /BYPASS  

Содержание DSI ES8300

Страница 1: ...ES8300 ACRYLIC BARRIER OPTICAL TURNSTILE INSTALLATION AND OPERATION INSTRUCTIONS...

Страница 2: ......

Страница 3: ...3 DESIGNED SECURITY INC 800 272 3555 www dsigo com 1402 Hawthorne Street Bastrop Texas 78602 Fax 512 321 9181 Email dsi dsigo com INS8300 CUSTOM NOTES...

Страница 4: ......

Страница 5: ...5 DESIGNED SECURITY INC 800 272 3555 www dsigo com 1402 Hawthorne Street Bastrop Texas 78602 Fax 512 321 9181 Email dsi dsigo com INS8300 SITE PREPARATION...

Страница 6: ......

Страница 7: ...straight forward installation when a little time is taken to prepare before you begin You may choose to take the time now to read and understand the installation and operation instructions in order t...

Страница 8: ......

Страница 9: ...9 DESIGNED SECURITY INC 800 272 3555 www dsigo com 1402 Hawthorne Street Bastrop Texas 78602 Fax 512 321 9181 Email dsi dsigo com INS8300 INSTALLATION...

Страница 10: ......

Страница 11: ...be taken in placing the bollards to ensure that the user may easily access the Reader System I E Mag Card Proximity Biometric etc provided by installer integrator while maintaining a reasonable flow...

Страница 12: ...ds is shown to help installers understand the proper placement of the Turnstiles in reference to the direction of traffic When entering the lane from the Secure side or Exit Side the Electronics Packa...

Страница 13: ...ng finish or creating a hazard to pedestrian traffic PANEL INSTALLATION STEPS Place panel on Hinge Points Tilt into place in Bollard Insert T Handle Hex key wrench into small hole near the top side ed...

Страница 14: ...can calculate the length of the long side C of any right angle triangle based upon the known length of the other two sides Use this device to verify alignment by referencing a chalk line on the floor...

Страница 15: ...N ENCODER BARRIER PANEL D SENSORS C SENSORS B A SENSORS MOTOR ELECTRONICS PACKAGE MOUNTING POINTS CABLE ACCESS MOUNTING POINTS CABLE ACCESS END VIEW B SIDE SHOWN The A Side of each Bollard will have e...

Страница 16: ...C Output Default Jumper covers upper and center pins for N O Output SET TRIMMERS setting of 10 1 second To reach top menu press M key 3 times Use down arrow to highlight 3 Trimmers Press Return Displ...

Страница 17: ...ve to allow a user to exit from the secure side although the barriers may always be pushed open in an emergency The D1 2 3 Sensors work similarly for users exiting from the secure side IE blocking thi...

Страница 18: ...el Below the Encoder is the Barrier Panel Located on the same shaft Units with optional Locking will have Locking Solenoid hardware mounted on this shaft This shaft goes into a shaft Coupler that allo...

Страница 19: ...WIRING...

Страница 20: ...lard when facing from the Entrance un secure side This bollard should have the Electronics Package in the side facing into the lane Leave adequate service loop in cables Route cables neatly in pedesta...

Страница 21: ...op Texas 78602 Fax 512 321 9181 Email dsi dsigo com INS8300 ENCODER 2 CONNECTOR DETAIL MOTOR 2 CONNECTOR DETAIL PIN COLOR 1 Shield 2 Black 3 Vacant 4 Red 5 White 6 Green PIN COLOR 1 White 2 Black 3 Sh...

Страница 22: ...sure which stows barriers N O Free Exit 15 16 Dry contact closure enables the Free Exit function N O Emergency 17 18 Dry contact closure moves Barriers to Exit activates alarm graphics and alarm relay...

Страница 23: ...p over long cable run from Power Supply may create a high current condition that trips the breaker Use appropriate gauge wire for your installation LIGHT ARRAY CONNECTIONS Entry local and Exit adjacen...

Страница 24: ......

Страница 25: ...SETUP OPERATION...

Страница 26: ......

Страница 27: ...e the one you are aiming for Primarily on A and B Sensors Adjust Sensor bracket for a good signal lock LED Off indicates the Sensor is in alignment with the Reflector and in a stable operating state L...

Страница 28: ...OR O O EXIT CARD O OR O O INVALID CARD O O O RESET BYPASS O O ENTRY CLOSED O EXIT CLOSED O ARM DISABLE O FREE EXIT EXIT WHEN D SENSOR IS BROKEN BY USER EMERGENCY O O VOICE ENABLE HORN DISABLE SILENT...

Страница 29: ...AY SOUND MOVE THROUGH THE LANE PROMPTLY Avoid stopping or moving backward as this will trigger the alarm TIP During passage through the lane swinging items purses briefcases etc could be interpreted b...

Страница 30: ...THEY SHOULD VISIT THE GUARD NOTE The single most frequent violation and cause of abuse results from Users pushing through the barriers It is important that the User be trained to NEVER touch the barr...

Страница 31: ...31 DESIGNED SECURITY INC 800 272 3555 www dsigo com 1402 Hawthorne Street Bastrop Texas 78602 Fax 512 321 9181 Email dsi dsigo com INS8300 APPENDIX...

Страница 32: ......

Страница 33: ...may optionally be N C see Page 16 N O Dry Contact for Alarm N O Dry Contact for Time Out N O Dry Contact for Valid Passage N O Dry Contact for Bypass N O Dry Contact for Invalid Card Accessory Power 1...

Страница 34: ...e in feet of actual Wire Run from power supply to the most remote load 125 Multiply figures from above two lines Match final number to Table below to determine Wire Gauge needed to provide adequate Vo...

Страница 35: ...ouble calls Pull Doors It is a good idea not to place the bollards immediately before a pull door The action of pulling the door open may cause the user to back into the lane This could generate a nui...

Страница 36: ...ay would be ideal Slowing traffic through the lanes minimizes false alarms generated through beam interruption by briefcases bags umbrellas coats etc A rapidly moving user could be swinging these item...

Страница 37: ...Automotive clear coat polishes work well for this application Turtle Wax s Clear Coat Polish and Restorer is what we use at the factory Powder Coat Painted Clean with mild soap water and a soft non ab...

Страница 38: ...a larger gauge smaller number or increase the Supply Voltage in order to deliver 24 VDC at the Power Input Connector while the ES8300 is operating under load Symptom Numerous False Alarms These Alarms...

Страница 39: ...nstalled used and maintained according to instructions DSI will for a period of three 3 years from date of purchase repair or replace any part which upon our examination proves to be defective under n...

Отзывы: