System errors and warnings
This topic describes error messages or warnings that may appear pre-flight or during flight. If the problem
persists, contact your Delair distributor.
Unable to arm the system
The system will not allow you to arm if the following errors are reported:
Error
To clear the error...
The eBox is not in the correct
state.
Cancel the checklist. Disconnect the battery from the rover and redo the
checklist.
The rover battery life is less
than 35%.
Restart the checklist with a fully charged battery.
The takeoff sensor is not OK
(this means that the yaw,
pitch, and roll values are not
yet stabilized).
If the issue does not resolve itself, cancel the checklist. Disconnect the
battery from the rover and restart the checklist.
The takeoff status is not OK.
Cancel the checklist. Disconnect the battery from the rover and redo the
checklist.
eBox logging has not started.
If the issue does not resolve itself, cancel the checklist. Disconnect the
battery from the rover and redo the checklist.
The GCS has no
GPS connection.
If the issue does not resolve itself, cancel the checklist. Disconnect the
battery from the rover and redo the checklist.
The number of satellites is less
than 4.
If the issue does not resolve itself, cancel the checklist. Disconnect the
battery from the rover and redo the checklist.
The flight plan contains a
waypoint located outside the
geofence.
Verify the geofence. If this does not resolve the issue, cancel the checklist.
Disconnect the battery from the rover and redo the checklist.