Exposure controls and personal protection
No engineering controls are required for handing batteries that have not been damaged.
Respiratory
protection:
Not necessary under normal use.
In case of battery rupture, use self contained full-face respiratory equipment.
Hand protection:
Not necessary under normal use.
Use gloves if handling a leaking or ruptured battery.
Eye protection:
Not necessary under normal use.
Wear safety goggles or glasses with side shields if handling a leaking or ruptured
battery.
Skin protection:
Not necessary under normal use.
Use rubber protective working in case of handling of a ruptured battery.
Physical and chemical properties
Temperature range:
Continuous
Occasional
In storage
+30 °C (86 °F) max.
-20 to +60 °C (-4 to +140 °F)
During discharge
-20 to +60 °C (-4 to +140 °F)
-20 to +60 °C (-4 to +140 °F)
During charge
0 to +45 °C (+32 to 113 °F)
0 to +45 °C (+32 to 113 °F)
Stability and reactivity
Conditions to avoid
Heat above 60 °C (140 °F) or incineration.
Deform, mutilate, crush, pierce, disassemble
Short circuit
Prolonged exposure to humid conditions.
Materials to avoid
N/A
Hazardous decomposition products
Fire, excessive heat, or over voltage conditions may produce hazardous decomposition products.
Toxicological information
1. Irritancy: The electrolytes contained in this battery can irritate eyes with any contact. Prolonged
contact with the skin or mucous membranes may cause irritation.
2. Sensitization: No information is available at this time.