System Setup and Configuration
3.8 Firmware Commands and Utilities Used in System Configuration
3. Enter
SET FORCEUNI 0
to override the default unit number value supplied
by the bus node ID plug.
4. Enter
SHOW UNITNUM
to verify the new unit number.
5. Enter
SHOW FORCEUNI
to verify that the current value for the
FORCEUNI
parameter is 0.
Example 3–7 shows the steps for changing the unit number of a specified
device from unit number 0 to unit number 10.
6. Label the device with its unit number, using the unit number labels
shipped with your system. Figure 3–10 shows where to affix a unit number
label on the device front panel.
Example 3–7 Setting a Unit Number for a Specified Device
PARAMS>SHOW UNITNUM
Parameter
Current
Default
Type
Radix
--------- ----------------
----------------
--------
-----
UNITNUM
0
0
Word
Dec
U
PARAMS>SET UNITNUM 10
PARAMS>SET FORCEUNI 0
PARAMS>SHOW UNITNUM
Parameter
Current
Default
Type
Radix
--------- ----------------
----------------
--------
-----
UNITNUM
10
0
Word
Dec
U
PARAMS>SHOW FORCEUNI
Parameter
Current
Default
Type
Radix
--------- ----------------
----------------
--------
-----
FORCEUNI
0
1
Boolean
0/1
U
3–40 System Setup and Configuration