KA681/KA691/KA692/KA694 Firmware Commands
A.2 Console Commands
A.2.15 SHOW
The SHOW command displays the console parameter you specify.
Format:
SHOW {parameter}
Parameters:
BFLAG
Displays the default R5 boot flags.
BOOT
Displays the default boot device.
CONTROLP
Shows the current state of Control-P halt recognition, either
Enabled or Disabled.
DEVICE
Displays all devices in the system.
HALT
Shows the user-defined halt action.
DSSI
Shows the status of all nodes that can be found on the DSSI
bus. For each node on the DSSI bus, the console displays the
node number, the node name, and the boot name and type of
the device, if available. The command does not indicate the
"bootability" of the device.
The node that issues the command reports a node name of "*".
The device information is obtained from the media type field of
the MSCP command GET UNIT STATUS. In the case where the
node is not running or is not capable of running an MSCP server,
then no device information is displayed.
DSSI_ID
Lists the DSSI node ID for each adapter.
ETHERNET
Displays hardware Ethernet address for all Ethernet adapters
that can be found. Displays as blank if no Ethernet adapter is
present.
LANGUAGE
Displays console language and keyboard type. Refer to the
corresponding SET LANGUAGE command for the meaning.
MEMORY
Displays main memory configuration board by board.
/FULL
—Additionally, displays the normally inaccessible areas
of memory, such as the PFN bitmap pages, the console scratch
memory pages, the Q22–bus scatter-gather map pages. Also
reports the addresses of bad pages, as defined by the bitmap.
A–34 KA681/KA691/KA692/KA694 Firmware Commands