![DEC KA681 Скачать руководство пользователя страница 117](http://html1.mh-extra.com/html/dec/ka681/ka681_system-maintenance_2461319117.webp)
System Initialization and Acceptance Testing (Normal Operation)
4.3 CPU ROM-Based Diagnostics
Scripts
#
Description
A0
User defined scripts
A1
Powerup tests, Functional Verify, continue on error, numeric
countdown
A3
Functional Verify, stop on error, test # announcements
A4
Loop on A3 Functional Verify
A5
Address shorts test, run fastest way possible
A6
Memory tests, mark only multiple bit errors
A7
Memory tests
A8
Memory acceptance tests, mark single and multibit errors,
call A7
A9
Memory tests, stop on error
>>>
4.4 Basic Acceptance Test Procedure
Perform the acceptance testing procedure listed below, after installing a
system, or whenever adding or replacing the following:
CPU module
MS690 memory module
Backplane
DSSI device
H3604 console module
1. While monitoring the test display on the console terminal, run five
error-free passes of the power-up scripts by entering the following
command:
>>>R T 0
If you cannot monitor the console terminal during this step, use the
following command.
>>>T A4
Script A4 will halt on an error so that the error message will not scroll off
the screen.
Press
CTRL/C
to terminate the scripts. Refer to Chapter 5 if failures occur.
2. Double-check the memory configuration, since test 31 can check for only
a few invalid configurations. For example, test 31 cannot report that a
memory board is missing from the configuration, since it has no way of
knowing if the board should be there or not.
System Initialization and Acceptance Testing (Normal Operation)
4–15