Jam 2
Paper Misfeed in PFU (Failure to Feed: Tray 2)
Message: Paper Misfeed: Tray 2
Jam Paper did not arrive at the relay sensor, so no signal from relay sensor
Cause:
• Feeler of relays sensor failed to return to its correct position
Problem Site
• Optional PFU (Tray 2)
• CTL board
Action
Perform check, take action in this order:
1. Inspect PFU for faulty parts and replace.
Jam 3
Paper Jam in Duplex Unit
Message: Paper Misfeed: Duplex Unit
Jam
Jam occurred when inverting sheet or printing 2nd side of duplex sheet. Paper late jam.
Trailing edge sensor failed to detect and signal the trailing edge of the sheet.
Cause:
• Duplex unit not operating correctly.
Problem Site
• Duplex unit
Action
Perform check, take action in this order:
1. Remove and reinstall duplex unit to confirm proper installation.
2. Open duplex unit cover and remove jammed paper, other obstruction.
3. Inspect duplex unit and replace damaged parts.
Jam 4
Paper Feed Jam in Duplex Unit
Message: Paper Misfeed: Guide Plate
Jam
Jam occurred when inverting sheet or printing 2nd side of duplex sheet. Paper lag jam.
Trailing edge sensor detected the leading edge of the paper but failed to detect and
signal the trailing edge because the paper stopped.
Cause:
• Paper jam or other obstruction at the trailing edge sensor
• Jammed paper or other obstruction in the paper path
• Trailing edge sensor feeler obstructed or damaged
Problem Site
• Trailing edge sensor
4. Troubleshooting
166
4
Содержание J012
Страница 1: ...Toscana C1a C1b C1bN Machine Code J012 J013 J014 SERVICE MANUAL July 2007 Subject to change ...
Страница 25: ...24 ...
Страница 44: ...Load Paper 1 Raise the output tray 2 Pull the paper tray out of the machine Installation Procedure 43 1 ...
Страница 63: ...1 Installation 62 1 ...
Страница 156: ...4 Service Data List 1 Menu Yes 1 SERVICE S CHOICE 2 or 4 REPORT Yes SERVICE DATA LIST Yes Status Reports 155 4 ...
Страница 158: ...Self Diagnostic Test Flow Self Diagnostic Test Flow 157 4 ...
Страница 159: ...4 Troubleshooting 158 4 ...
Страница 160: ...Self Diagnostic Test Flow 159 4 ...
Страница 199: ...4 Troubleshooting 198 4 ...
Страница 212: ...T 30 PROTOCOL MONITOR REPORT 5 CLEAR DATA These settings clear memory and all memory settings Service Mode 211 5 ...
Страница 306: ...Ink Supply Overview 1 Ink cartridges x 4 Y M C K 2 Ink Pump Unit 3 Ink Supply Tubes Ink Supply 305 6 ...
Страница 330: ...Basic Operation Initialization Sequence at Power On Basic Operation 329 6 ...
Страница 332: ...Duplex Unit Overview 1 Duplexer Cover Button 2 Duplexer Cover 3 4 Duplexer Locks x 2 Duplex Drive Duplex Unit 331 6 ...
Страница 339: ...ADF Overview 1 ADF 2 Original Tray Drive 1 Paper Feed Roller 2 Paper Feed Clutch 6 Detailed Section Descriptions 338 6 ...
Страница 340: ...3 Original Feed Motor 4 Pick up Roller ADF 339 6 ...
Страница 341: ...6 Detailed Section Descriptions 340 6 ...
Страница 364: ...MEMO 363 ...
Страница 365: ...MEMO 364 ...