I-Class
Diagnostics (continued)
Menu Item
Details
SENSOR READINGS
Displays A-D sensor values (0 – 255), where:
THR TRAN RIBM 24V
127 159 093 175
PS HD RANK
000 254 000
Are the sensor readings, where:
•
THR = Printhead thermistor sensor;
•
TRAN = Media sensor when set to Gap or Continuous, or
REFL when to Reflective;
•
RIBM = Ribbon sensor;
•
24V = 24 VDC sensor;
•
PS = Present sensor;
•
HD = Printhead position sensor; and,
•
RANK = Printhead ranking resistor.
Note: Readings provided here are examples only.
RIBBON SENSOR LIMITS
Displays the values from the ribbon sensor (when
equipped with the thermal transfer option), where:
RIBBON ADC LOW HIGH
070 104
Are the sensor readings (actual values will vary).
4.2.8 MCL Options
The MCL Options menu contains alternate operating selections:
Menu Item
Details
MCL OPTIONS
Allows the optional MCL (Macro Command Language)
tool suite to accept peripheral input data, where:
MCL AT POWER-UP
Allows MCL operation to begin when the printer is
turned ON, where:
DISABLED
No MCL operation.
MCL LINK MODE
Starts MCL in Link Mode.
MCL PROGRAM MODE
Starts MCL in Program Mode.
START MCL
Starts MCL after exiting the menu.