I-Class
5.8 Boot Loader Updates
The printer stores its Boot Loader program in Flash memory on the main logic card.
WARNING
If power is lost while UPGRADING SOFTWARE is displayed, the printer will
become non-functional and will require factory programming or a main logic
card.
Before updating, identify the current program version by printing a Configuration Label (see
Section 4.3.2). Compare that version string to those available from our web site then
download the desired file onto your computer’s hard drive. Follow the steps below to update
the version:
Boot Loader Update Procedure
Step
Displayed Message
Action
Comment(s)
1 READY
Using the DOS copy
command (where
“filename” is the
program to be loaded
and “lpt1” is the
selected interface
port), enter the
following:
copy filename lpt1:
As an example, this would be
entered as:
copy boottb99_1101.bs lpt1
(Where “lpt1” can differ to
include another port, as
equipped.)
The Ready Indicator will flash
as data is received.
2
UPGRADING SOFTWARE
No action required.
The new program is being
stored and verified.
3
4212
11.05 03/26/2008
No action required.
The printer has reset
automatically.
4
READY
No action required.
The new application is now
running.
Note: If UNCALIBRATED is
displayed, see Section 5.2.
Note: If the update failed, press and hold the PAUSE and TEST Keys (see Section 4.1)
while turning ON the printer. After SEND SOFTWARE is displayed, release the
keys then re-send the file as described above.